10/18/2024
1:37 AM
 
Permit No. BLDG2107-0320 Permit Type   INTERIOR REMODEL Site Address   6206 NW 66 AVE
PARKLAND, FL 33067
Applied   07/29/2021 Applicant  
Approved   09/22/2023 Owner   MORSILLO,SIMONE ALMEIDA
Issued   10/09/2023 Contractor   OWNER / BUILDER
Parent Permit No.   Description   GARAGE RENOVATION
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

FINAL**Wyatt T. Haygood

PLUMBING FINALJan Trana

MECHANICAL FINALDave Chin-Sang

 11/15/2023NOCDebbie GrosseAPPROVED

 11/29/2023GROUND ROUGHJan TranaDISAPPROVEDeTRAKiT Inspection Request11/28/2023 11:54:35 AM 11/28/2023 11:54 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5614005725 e-Mail: PERMITS@ADVBUILDING.COM 11/29/2023 10:56:24 AM No water in sanitary

 11/30/2023GROUND ROUGHJan TranaAPPROVEDeTRAKiT Inspection Request11/29/2023 12:15:08 PM 11/29/2023 12:15 PM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5614005725 e-Mail: PERMITS@ADVBUILDING.COM 11/30/2023 12:05:37 PM Cop by final

 03/14/2024SOIL TERMITE TREATBill TracyAPPROVEDeTRAKiT Inspection Request3/14/2024 8:02:53 AM 3/14/2024 8:03 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/14/2024 6:00:47 PM TRENCH SPOT - .05% CENTERFIRE

 03/15/2024SLABJoseph RobinsonDISAPPROVEDeTRAKiT Inspection Request3/14/2024 7:44:35 AM 3/14/2024 7:44 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/15/2024 11:06:16 AM Not ready for inspection.

 03/18/2024CONDENSATE LINEDave Chin-SangAPPROVEDeTRAKiT Inspection Request3/14/2024 7:47:15 AM 3/14/2024 7:47 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/18/2024 8:42:22 AM From attic terminate by C/U

 04/01/2024SLABTony WillsonAPPROVEDeTRAKiT Inspection Request3/28/2024 3:13:41 PM 3/28/2024 3:14 PM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/28/2024 11:10:31 PM 3/28/2024 11:10 PM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 4/1/2024 11:11:42 AM Plumbing Trench Repair.

 04/09/2024FRAMINGTony WillsonDISAPPROVED4/9/2024 12:01:12 PM 1) Masonry infill at the pool side wall was not tied into the beam or column with rebar. Remove and start again. 2) Foam all wall and ceiling penetrations. Concrete on anything exterior and foam interior. 3) Please make sure the plumbing and mechanical departments are ok with closing the walls up after framing and drywall. FBC 110.9.1

 04/12/2024FRAMINGC.A.P. Gov STDISAPPROVEDeTRAKiT Inspection Request4/11/2024 4:40:00 PM 4/11/2024 4:40 PM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 4/12/2024 12:13:44 PM 1. REVISION IS REQUIRED. APPROVED BY PARKLAND BUILD. DEPT. FOR THE ADDITIONAL OPENINGS IN THE SHOWER. 2. PREVIOUS INSPECTIONS REQUIRED a. FILLED CELLS b. WINDOW/DOOR BUCKS c. ELECTRICAL ROUGH, PLUMBING TOP OUT & MECHANICAL ROUGH 3. FURRING IS NOT COMPLETE 4. DRAFT STOP @ CEILING 110.8.5.7, 110.3, 110.6, 107.4 JS - PER DEREK OF CAP

 03/05/2024ELECTRIC ROUGHPedro VieiraDISAPPROVED3/6/2024 7:16:14 AM Partial approval Stated on plans the walls that are ok to close after receiving requested pictures. 3/6/2024 7:16:20 AM gave a partial approval with a condition of sending me pictures of the penetrations of wires thru the attic and around the boxes on concrete block wall foamed. Didn't receive the pictures so I disapproved it.

 02/26/2024ELECTRIC ROUGHPedro VieiraCANCELLED BY PERMITE2/26/2024 7:55:27 AM JR LIMA

 02/29/2024ELECTRIC ROUGHJoe NievesCANCELLED BY PERMITEafternoon if possible2/26/2024 7:56:52 AM JR LIMA 2/28/2024 7:41:26 AM 2/28/2024 7:41 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 2/29/2024 7:55:13 AM JS - CANCELLED AND RESCHEDULED FOR 3/5

 06/21/2024ELECTRIC ROUGHRinor KrasniqiAPPROVED

 03/12/2024ELECTRIC ROUGHRinor KrasniqiPARTIAL APPROVALeTRAKiT Inspection Request3/11/2024 5:05:48 PM 3/11/2024 5:06 PM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/12/2024 12:41:28 PM Bathroom and kitchen elec rough

 03/18/2024ELECTRIC ROUGHJoe NievesPARTIAL APPROVALeTRAKiT Inspection Request3/14/2024 7:44:13 AM 3/14/2024 7:44 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/14/2024 8:09:37 AM 3/14/2024 8:09 AM ADVANCED BUILDING CONTRACTORS INC Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 3/18/2024 1:57:06 PM PARTIAL ELECTRIC ROUGH APPROVED PENDING/ LOAD-CENTER WORK, FEEDER AND BRANCH CIRCUIT COMPLETION/ FBC-BCA 110.9.1 OK TO CLOSE WALLS.

 04/08/2024FRAMINGTony WillsonCANCELLED BY PERMITECheck MEP's Approvals.

 04/18/2024FRAMINGTony WillsonDISAPPROVEDeTRAKiT Inspection Request4/17/2024 7:40:53 AM 4/17/2024 7:41 AM ADVANCED BUILDING CONTRACTORS INC am please if possible Contact Name: ADVANCED BUILDING CONTRACTORS INC Site Address: 6206 NW 66 AVE Phone: 5615990767 e-Mail: PERMITS@ADVBUILDING.COM 4/18/2024 2:56:43 PM No framing inspection before all and any changes made by the owners are submitted to the building department as a change of plan. AFBC 110.9.1 1) Added a window in the bathroom pool side. Architect or Engineer to address and document all COP. SUBMIT to BUILDING DEPARTMENT BEFORE CONTINUING PLEASE. 2) Please decide if the existing windows will be removed and replaced with new HVHZ products like submitted. If not this will be another change of plans because the existing windows. will have to be shuttered if non-impact. 3) Please get the mechanical rough and plumbing rough approvals out of the way like discussed.

 07/17/2024SHOWER PANJan TranaAPPROVED

 07/17/2024SPOT SURVEYAPPROVEDCheck Ex. Garage Slab Elevation4/4/2024 4:21:59 PM Inspection voided by BD35. Most recent remarks follow: SLAB ELEVATION 7/17/2024 6:03:45 PM SURVEY SHOWS SLAB ELEVATION AT 17.03 OR HIGHER (18.74)

 04/04/2024TIE BEAM/BONDTony WillsonAPPROVED4/4/2024 4:25:39 PM Infills at Overhead Garage Door. No beam only FC's. Engineer Inspected & will supply a Unit Masonry Letter.

 07/17/2024TOP OUTJan TranaAPPROVED7/17/2024 12:01:04 PM There are no air shock for dishwasher in wall at this time.

 07/25/2024DRYWALL SCREWWyatt T. HaygoodCANCELLED BY PERMITE7/23/2024 11:09:02 AM MT

 07/25/2024WIND/DOOR BUCKWyatt T. HaygoodCANCELLED BY PERMITE7/23/2024 11:09:33 AM MT

 07/29/2024WIND/DOOR BUCKTony WillsonPARTIAL APPROVAL7/29/2024 3:23:54 PM Approved only 1 window and 2 doors on the west elevation wall. (Front)

 07/30/2024EXHAUST ROUGHDave Chin-SangDISAPPROVED7/29/2024 11:58:31 AM vb 7/30/2024 9:12:28 AM No dryer exhaust in laundry closet . Walls covered

 07/30/2024ROUGH DUCTDave Chin-SangDISAPPROVED7/29/2024 11:58:42 AM vb 7/30/2024 9:12:29 AM No ladder for attic inspection. Not ready. Room Transfer cut-outs not installed Return grill size not per plan.

 07/30/2024INSULATIONJoseph RobinsonDISAPPROVED7/29/2024 11:53:22 AM JS 7/30/2024 4:30:58 PM Work covered by drywall. Please follow inspection sequence.

 07/31/2024FRAMINGJoseph RobinsonDISAPPROVED7/31/2024 3:55:55 PM Insulation and drywall installed prior to framing approval. 2 sheets of drywall removed to verify framing method and insulation. Work appears to be ok. Please schedule other trade inspections and follow inspection sequence.

 08/07/2024FINAL SURVEYBill TracyPARTIAL APPROVAL8/7/2024 2:01:04 PM ELEVATION CERTIFICATE SUBMITTED - NEED SURVEY TO COMPLETE THIS REQUIREMENT

 08/08/2024FRAMINGJoseph RobinsonCANCELLED BY DEPTPending COP

 08/08/2024WIND/DOOR BUCKJoseph RobinsonCANCELLED BY DEPTPending COP

 08/08/2024EXHAUST ROUGHDave Chin-SangDISAPPROVED8/8/2024 10:14:37 AM BXF not ducted to exterior. FBC/Res M1501.1 Dryer exhaust duct incorrect material. Smooth wall duct required.FBC/Residential M1502.4.1

 08/09/2024DRYWALL SCREWJoseph RobinsonCANCELLED BY DEPTPending COP8/7/2024 2:35:05 PM ST

 08/09/2024ROUGH DUCTDave Chin-SangAPPROVED8/7/2024 2:34:41 PM ST

 08/12/2024DRYWALL SCREWTony WillsonDISAPPROVED8/9/2024 4:02:48 PM mt 8/12/2024 1:11:41 PM Screws were missing throughout the building. Went over everything with the crew. FBC 110.9.1

 08/12/2024WIND/DOOR ATTACHMENTTony WillsonDISAPPROVED8/9/2024 4:04:48 PM mt 8/12/2024 1:11:43 PM Please have the Product Approvals onsite for all new doors and windows. FBC 107.3.1

 08/12/2024FRAMINGTony WillsonAPPROVED8/9/2024 4:04:31 PM mt

 08/19/2024DRYWALL SCREWTony WillsonAPPROVED8/15/2024 2:52:51 PM JS

 08/20/2024EXHAUST ROUGHScott WieselDISAPPROVED8/19/2024 11:38:32 AM ST 8/20/2024 12:29:38 PM Need to seal dryer vent need ladder to attic set up for inspection

EXHAUST ROUGHDave Chin-Sang

 08/21/2024EXHAUST ROUGHScott WieselAPPROVED8/20/2024 11:56:01 AM ST

 09/05/2024INSULATIONTony WillsonAPPROVED

 09/11/2024FINAL SURVEYBill TracyAPPROVED

 09/18/2024WIRE LATHTony WillsonAPPROVED9/17/2024 10:02:43 AM MT 9/18/2024 4:42:56 PM Lath on 2 door headers only. New doors facing West. 9/19/2024 11:23:08 AM Wire Lath above 2 new exterior doors only.

 09/18/2024WIND/DOOR ATTACHMENTTony WillsonDISAPPROVED9/17/2024 10:02:26 AM MT 9/18/2024 4:45:28 PM Missing NOA's. New Shower window was not installed. FBC 110.9.1

WIND/DOOR ATTACHMENTBill Tracy

 09/19/2024ELECTRIC FINALJoe NievesDISAPPROVED9/17/2024 10:02:59 AM MT 9/19/2024 10:22:27 AM AN APPROVED PLAN MATCHING ACTUAL FIELD INSTALLATION REQUIRED FOR FINAL ELECTRIC INSPECTION/FBC-BCA 107.3.1.5

ELECTRIC FINALJoe Nieves

 09/20/2024SEWER CONNECTIONJan TranaDISAPPROVEDREQUESTING FINAL9/18/2024 11:14:26 AM FM 9/18/2024 2:25:16 PM JS - RESCHEDULED FROM 9/19/2024 9/19/2024 1:48:07 PM MT-CX BY OWNER 9/20/2024 11:10:22 AM Work covered,not ready

SEWER CONNECTIONJan Trana