09/07/2024
10:32 PM
 
Permit No. BLDG2111-0155 Permit Type   ADDITION Site Address   6132 NW 88 AVE
PARKLAND, FL 33067
Applied   11/16/2021 Applicant  
Approved   01/18/2022 Owner   JORDAN-KALIDYN,LARA
Issued   01/21/2022 Contractor   OWNER/BUILDER
Parent Permit No.   Description   ADDITION
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ADMIN CHECKLIST**Victoria Barrios

 01/21/2022NOCDebbie GrosseAPPROVED

 02/25/2022SOIL BEARING CERTBill TracyAPPROVED2/25/2022 2:13:46 PM COMPACTION REPORT SUBMITTED

 02/25/2022SOIL TERMITE TREATBill TracyAPPROVED2/25/2022 2:15:48 PM .05% IMIDACLOPRID

 02/25/2022TRUSS PLANS ON FILEBill TracyAPPROVED2/23/2022 2:43:01 PM SPOKE WITH O/B - TOLD HIM WE NEED TRUSS ENGINEERING SUBMITTED, OR, A LETTER FROM THE TRUSS COMPANY STATING THE TRUSS LAYOUT WILL MATCH THE ROOF FRAMING PLAN FROM THE ARCHITECT

 12/17/2021PRODUCT APPROVALSBill TracyAPPROVED

 02/28/2022SERVICE GROUNDJoe NievesAPPROVEDSEE NOTES2/25/2022 2:14:50 PM SMALL ADDITION - VERIFY IF REQUIRED OR N/A INSPECTION 2/28/2022 2:23:24 PM Service Ground Inspection Not Required.

 02/28/2022SLABTony WillsonAPPROVED

 03/08/2022SPOT SURVEYBill TracyAPPROVED3/8/2022 6:12:01 PM SHADED X ZONE

 03/22/2022TIE BEAM/BONDJoseph RobinsonDISAPPROVED3/21/2022 4:05:10 PM ST 3/22/2022 1:40:12 PM Special inspector approval required before this inspection.

 03/23/2022ELECTRIC DEMODean DiBisceglieAPPROVED3/22/2022 2:24:34 PM MT

 04/21/2022TIE BEAM/BONDJoseph RobinsonAPPROVED4/20/2022 3:14:06 PM JS

 06/02/2022ROOF SHEATHINGJoseph RobinsonPARTIAL APPROVAL6/1/2022 3:39:52 PM vb 6/2/2022 2:28:25 PM Partial pending sheathing for rake beam area.

 06/02/2022FRAMINGWyatt T. HaygoodCANCELLED BY PERMITE6/1/2022 3:40:04 PM vb 6/1/2022 3:53:38 PM MT-CX BY ALON

 07/19/2022FRAMINGJoseph RobinsonDISAPPROVED7/18/2022 12:07:21 PM vb 7/19/2022 4:10:04 PM Framing not started. House not ready for framing inspection.

 08/03/2022ROOF SHEATHINGWyatt T. HaygoodAPPROVED8/3/2022 7:53:57 AM wth

 08/03/2022WALL SHEATHINGWyatt T. HaygoodAPPROVED8/3/2022 8:13:16 AM wth

 08/03/2022TRUSSWyatt T. HaygoodAPPROVED8/3/2022 7:54:10 AM wth

 11/14/2023FOOTER/FOUNDATIONAnthony CrisantiAPPROVEDCOP Bill / For SGD11/14/2023 7:44:56 AM 8-12

 11/13/2023NOCStephanie TaylorAPPROVEDCOC OWNER/BUILDER

 11/15/2023TIE BEAM/BONDAnthony CrisantiAPPROVEDSEE COP11/15/2023 12:08:53 PM This is not an actual tie beam but additional 2x's to bring out the original tie beam to match new additional footer pour of 5"

 11/17/2023UNIT MASONRY CERTBill TracyAPPROVED11/17/2023 1:51:26 PM NOT REQUIRED DUE TO SIZE OF PROJECT

 11/29/2023WIND/DOOR BUCKAnthony CrisantiDISAPPROVED11/29/2023 7:28:34 AM 9-12 11/29/2023 11:32:49 AM Not ready ?.. courtesy visit for new sliders (engineer to design repair aspect)

 11/29/2023WIND/DOOR ATTACHMENTAnthony CrisantiDISAPPROVED11/29/2023 7:28:20 AM 9-12 11/29/2023 11:32:51 AM Not ready

 01/26/2024WIND/DOOR BUCKAnthony CrisantiAPPROVED1/25/2024 2:55:28 PM MT 1/26/2024 7:38:42 AM 8-12 1/26/2024 4:02:04 PM Single door to be change. COP to be submitted

 01/31/2024TIN CAPAnthony CrisantiAPPROVEDCheck Notes1/31/2024 5:12:38 PM Tin Cap passed on 1-17-23 by WTH as a part of the reroof permit 2212-0197

 01/31/2024HOT MOP IN PROGRESSAnthony CrisantiAPPROVEDCheck Notes1/31/2024 5:14:30 PM Hot Mop in Progress passed on 1-17-23 by WTH as a part of the reroof permit 2212-0197

 01/31/2024TILE IN PROGRESSAnthony CrisantiAPPROVEDcheck notes1/31/2024 5:16:09 PM Tile in progress passed on 1-17-23 by WTH as a part of re-roof permit 22121-0197

 01/31/2024ROOF TILE UPLIFT TSTAnthony CrisantiAPPROVEDCheck notes1/31/2024 5:18:17 PM Uplift test passed on 2-3-23 by BD26 as a part of the re-roof permit 2212-0197

 01/31/2024ROOF FINALAnthony CrisantiAPPROVEDsee notes1/31/2024 5:19:43 PM Passed on 5-10-23 by BD37 as a part of re-roof permit 2212-0197

 02/01/2024WIND/DOOR ATTACHMENTAnthony CrisantiPARTIAL APPROVAL1/31/2024 3:06:17 PM FM 2/1/2024 12:31:10 PM Room addition good to go noted on plan. Side door to be changed, COP is being submitted to city next week. Main slider not approved as there is an issue with the track size and is being reviewed by PGT but will not affect the continuation of the bedroom addition.

 03/14/2024ELECTRIC ROUGHRinor KrasniqiAPPROVED3/12/2024 2:23:08 PM MT

 03/14/2024WIRE LATHAnthony CrisantiAPPROVED3/12/2024 4:25:17 PM FM

 03/22/2024FRAMINGAnthony CrisantiDISAPPROVED3/21/2024 4:44:21 PM MT

 03/28/2024FRAMINGAnthony CrisantiAPPROVED3/28/2024 4:21:23 PM Mechanical needs to be inspected in one section of wall check to see that the drainage pipes are filled before installing the drywall on that wall.

FINALJoseph Robinson

 04/02/2024MECHANICAL FINALDave Chin-SangDISAPPROVED4/2/2024 7:58:01 AM JS 4/2/2024 10:39:23 AM Permit paperwork not on site. FBC/Res M1411.3.1 condensate overflow protection required. Drain lies need to be supported and connected in an approved manor M305.4 Provide elevation certificate to show C/U not installed in flood zone Access panels required in walls for mini-split connections. FBC 306.1

 04/02/2024INSULATIONJoseph RobinsonPARTIAL APPROVALIS ASKING FOR A PARTIAL3/29/2024 11:35:28 AM MT-IS ASKING FOR A PARTIAL 4/2/2024 4:37:44 PM Partial for addition only. Section of main house near sliders not inspected.

 04/05/2024MECHANICAL FINALDave Chin-SangPARTIAL APPROVAL4/5/2024 8:25:35 AM Ok to cover wall . Access doors required.

 04/16/2024WIND/DOOR ATTACHMENTJoseph RobinsonAPPROVEDSee COP4/15/2024 7:47:29 AM VB

 04/18/2024DRYWALL SCREWTony WillsonAPPROVED4/17/2024 3:07:38 PM JS

 06/04/2024LOW VOLTAGE ROUGHJoe NievesAPPROVEDTV6/4/2024 12:38:53 PM LOW VOLTAGE ROUGH NOT REQUIRED

 06/06/2024ELECTRIC FINALRinor KrasniqiAPPROVED

 06/12/2024INSULATIONJoseph RobinsonAPPROVED4/4/2024 10:32:30 AM FM 4/5/2024 7:49:37 AM JS - STAFFING SHORTAGE DUE TO HOUSE FIRE INVESTIGATION

 06/12/2024FRAMINGJoseph RobinsonAPPROVED

 07/01/2024MECHANICAL FINALScott WieselAPPROVED

 07/01/2024CONDENSATE LINEScott WieselAPPROVEDREQUESTING FINAL6/28/2024 10:39:17 AM FM

 07/01/2024LOW VOLTAGE FINALRinor KrasniqiAPPROVEDTV6/28/2024 10:39:42 AM FM

 09/04/2024FINAL SURVEYBill TracyAPPROVED9/4/2024 3:18:42 PM SHADED X ZONE