09/07/2024
10:27 PM
 
Permit No. BLDG2206-0287 Permit Type   COMMERCIAL BUILD-OUT Site Address   10001 OLD CLUB RD
PARKLAND, FL 330763906
Applied   06/28/2022 Applicant   MARY BANMILLER
Approved   12/20/2022 Owner   PARKLAND GOLF & COUNTRY CLUB
Issued   01/03/2023 Contractor   ORIGIN CONSTRUCTION LLC
Parent Permit No.   Description   INTERIOR REMODEL/ADDITION OF PGCC CLUBHOUSE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 01/03/2023NOCDebbie GrosseAPPROVED

 01/12/2023MECHANICAL DEMODave Chin-SangAPPROVED1/11/2023 2:59:55 PM CJ 1/12/2023 10:32:30 AM Phase 1 kitchen equipment and hood demolished. Exposed electrical wires to old equipment is being dealt with by David Hayes at the time of inspection

 01/12/2023ELECTRIC DEMODavid HayesPARTIAL APPROVAL1/11/2023 3:00:13 PM CJ 1/12/2023 2:12:23 PM Please reschedule Demo once Demo is complete. Remove all hanging flex and data speaker tv. Support,and protect all cable that is needed to remain. Identify both ends of all low voltage cables. Remove all hanging power and lighting cables,to the closest junction box. Kill power to all sub panels in the construction area. Use only quad gfi receptacles to be the only outlets to remain energized for the course of construction. A lock out tag out procedure may be written out on letterhead and signed by the qualifier and approved prior to implementation at a later date as it becomes necessary. Please call with any questions.

 01/23/2023ELECTRIC DEMOJoe NievesAPPROVED1/20/2023 3:07:53 PM CJ

 02/22/2023SOIL BEARING CERTWyatt T. HaygoodAPPROVED

 02/22/2023FOOTER/FOUNDATIONWyatt T. HaygoodDISAPPROVED2/22/2023 1:24:40 PM wth 2/22/2023 3:12:12 PM Transverse bars required to be 12 inch on center maximum. Provide detail from engineer of record for PVC Pipe Chases through Footings.

 01/12/2023DEMO STRUCTURALJoseph RobinsonPARTIAL APPROVAL1/11/2023 3:00:27 PM CJ 1/12/2023 3:03:55 PM Interior demo complete.

 02/23/2023FOOTER/FOUNDATIONWyatt T. HaygoodAPPROVED2/22/2023 3:12:43 PM wth

 02/16/2023FOOTER/FOUNDATIONWyatt T. HaygoodDISAPPROVED2/15/2023 3:37:22 PM MT 2/16/2023 11:29:41 AM Soil Bearing Certificate required to be submitted to city of parkland building department prior to foundation inspection.

 02/24/2023GROUND ROUGHJeremy HassenplugPARTIAL APPROVAL1/27/2023 11:43:27 AM MT 2/24/2023 12:33:20 PM grease for existing kitchen ok

 03/10/2023GROUND ROUGHJeremy HassenplugPARTIAL APPROVAL3/9/2023 1:23:34 PM an 3/10/2023 12:04:18 PM Kitchen sanitary and grease done

 03/14/2023UNDERGROUNDRinor KrasniqiAPPROVED3/13/2023 2:19:19 PM VB

 03/16/2023GROUND ROUGHJeremy HassenplugAPPROVED3/15/2023 9:58:34 AM ST

 03/27/2023SLABWyatt T. HaygoodPARTIAL APPROVAL3/24/2023 10:23:34 AM cj 3/27/2023 12:14:23 PM Slab repairs at kitchen and dining areas

 04/03/2023SOIL TERMITE TREATWyatt T. HaygoodPARTIAL APPROVAL4/3/2023 7:54:06 AM Soil Termite treatment for slab repairs approved

 01/30/2023RAIN WATER ROUGH INJan TranaPARTIAL APPROVAL1/30/2023 11:44:25 AM 8" storm drain under kitchen

 02/10/2023RAIN WATER ROUGH INJan TranaPARTIAL APPROVAL2/8/2023 1:41:35 PM VB 2/10/2023 1:06:05 PM Eight inch line below bar Missing connection to existing COP showing new location required by final

 02/15/2023RAIN WATER ROUGH INJeremy HassenplugPARTIAL APPROVAL2/14/2023 9:49:48 AM CJ 2/15/2023 11:31:03 AM Bar area rain water

 04/04/2023SLABJoseph RobinsonAPPROVED4/3/2023 9:09:41 AM wth

 04/04/2023SOIL TERMITE TREATJoseph RobinsonAPPROVED4/3/2023 9:10:24 AM wth

 04/05/2023ELEC WALL ROUGHPedro VieiraPARTIAL APPROVAL4/4/2023 4:01:39 PM MT 4/5/2023 11:07:40 AM Partial approval, please see notes on the plans at job site.

 04/26/2023SPOT SURVEYWyatt T. HaygoodAPPROVED

 04/27/2023TIE BEAM/BONDJoseph RobinsonDISAPPROVED4/26/2023 1:52:54 PM MT 4/27/2023 12:22:16 PM Tie beam incomplete. Complete tie beam and clean fill cells. Work incomplete.

 04/27/2023COLUMNJoseph RobinsonDISAPPROVED4/26/2023 1:52:35 PM MT 4/27/2023 12:22:17 PM Tie beam incomplete. Complete tie beam and clean fill cells. Work incomplete.

 04/28/2023COLUMNWyatt T. HaygoodDISAPPROVED4/27/2023 1:46:58 PM an 4/28/2023 11:43:58 AM an 4/28/2023 12:00:34 PM (1). Tie Beam not as per plan. (2). # 4 hooked Dowels not installed as per plan. Provide details from Engineer of Record and Change of plan with permit application.

 04/28/2023TIE BEAM/BONDWyatt T. HaygoodDISAPPROVED4/27/2023 1:48:29 PM an 4/28/2023 12:02:00 PM (1). Tie Beam not as per plan. (2). # 4 hooked Dowels not installed as per plan. Provide details from Engineer of Record and Change of plan with permit application.

 05/01/2023TOP OUTJeremy HassenplugPARTIAL APPROVAL4/28/2023 10:37:19 AM JS 5/1/2023 11:33:46 AM top out inside existing building is good

 05/01/2023TIE BEAM/BONDWyatt T. HaygoodPARTIAL APPROVAL4/28/2023 12:02:21 PM wth 5/1/2023 1:22:00 PM for bar area only Approved pending Change of plan submittal for tie beams. approved with alternate beam detail.

 05/01/2023COLUMNWyatt T. HaygoodAPPROVED4/28/2023 12:01:06 PM wth

 05/05/2023RAIN WATER ROUGH INJan TranaPARTIAL APPROVAL2/23/2023 10:09:49 AM ST 5/4/2023 12:48:47 PM mt 5/5/2023 12:48:30 PM 10" SDR 35 storm line from bldg to catch basin

 05/08/2023PIPE JOINT&MUD WORKPARTIAL APPROVALTie-in to existing YD

 05/09/2023RAIN WATER ROUGH INJan TranaAPPROVED

 05/09/2023PIPE MATERIALPerry TabornPARTIAL APPROVAL

 05/10/2023TIE BEAM/BONDJoseph RobinsonDISAPPROVED5/9/2023 11:29:14 AM an 5/10/2023 4:01:27 PM 1. Provide detail for started columns. 2. Provide detail for connecting tie beam to existing structure. 3. Provide change of plans for openings not installed. 4. Starter column rebar not epoxied in multiple areas. Expose all rebar for starter columns to inspect epoxy. Work incomplete.

 05/15/2023DECK STEEL/PAVERSJoseph RobinsonDISAPPROVED5/11/2023 10:28:25 AM MT 5/12/2023 4:40:04 PM Couldnt find city approved plans on site. I am assuming this inspection is for the patio slab under lanai. The slab is already cracking. I'm leaving this inspection open for Monday. 5/15/2023 1:01:49 PM Approved plans must be on site for all inspections.

 05/18/2023TIE BEAM/BONDJoseph RobinsonDISAPPROVED5/17/2023 9:23:15 AM ST 5/18/2023 4:02:09 PM Address comments from previous inspection. 5/24/2023 10:07:13 AM Address comments from previous inspection.

 05/16/20232ND FLOOR SLAB STRWyatt T. HaygoodPARTIAL APPROVAL5/16/2023 8:46:21 AM wth 5/16/2023 3:02:11 PM Steel I Beams and Steel Pan

 05/23/20232ND FLOOR SLAB STRJoseph RobinsonAPPROVED5/22/2023 3:20:34 PM wth

 05/30/2023TIE BEAM/BONDJoseph RobinsonDISAPPROVED5/26/2023 10:30:19 AM JS 5/30/2023 2:53:43 PM 1. Provide detail for started columns. 2. Provide detail for connecting tie beam to existing structure. 3. Provide change of plans for openings not installed. 4. Starter column rebar not epoxied in multiple areas. Expose all rebar for starter columns to inspect epoxy. Work incomplete.

 05/31/2023TIE BEAM/BONDWyatt T. HaygoodPARTIAL APPROVAL5/30/2023 3:32:55 PM VB 5/31/2023 10:08:33 AM kitchen area and one opening at new dining area.

 06/13/2023DEMO STRUCTURALJoseph RobinsonDISAPPROVED6/13/2023 11:31:58 AM Engineer must address all cut rebar in all openings cut into existing structure.

 06/21/2023FRAMINGJoseph RobinsonDISAPPROVED6/20/2023 8:02:54 AM wth 6/21/2023 11:06:41 AM Inspection for second floor pilasters. Provide clarification of building material. Plans do not specify metal gauge. Plans specify FRT wood. Plans do not have an attachment detail for framing to deck connection.

 06/27/2023WIND/DOOR BUCKJoseph RobinsonDISAPPROVED6/27/2023 3:35:03 PM Not ready for inspection. Provide repair letter or letter of clarification for rebar cut in new openings.

 06/28/2023TIE BEAM/BONDJoseph RobinsonDISAPPROVED6/27/2023 8:54:30 AM FM 6/28/2023 1:08:03 PM Tie beam does not match detail from engineer. See markings on detail. Work incomplete. 6/28/2023 1:09:49 PM Tie beam does not match detail from engineer. See markings on detail. Work incomplete.

 06/29/2023WIND/DOOR BUCKJoseph RobinsonPARTIAL APPROVAL6/28/2023 12:31:59 PM VB 6/29/2023 2:14:35 PM Bucks approved for all openings that don't need a poured beam.

 06/30/2023TIE BEAM/BONDAlejandro CorralesDISAPPROVED - FEE6/29/2023 2:20:55 PM FM 6/30/2023 5:03:22 PM 1) 4th time scheduling inspection. Tie-beam not per detail from engineer. Engineer calls for steel to be lapped over bearing points and not mid-span. Steel was lapped mid-span on site. 2) All steel in tie-beam was not properly epoxied. Rebar came loose from embedment points with a hit of the hammer. Check epoxy at next inspection. 6/30/2023 5:04:42 PM 1) 4th time scheduling inspection. Tie-beam not per detail from engineer. Engineer calls for steel to be lapped over bearing points and not mid-span. Steel was lapped mid-span on site. 2) All steel in tie-beam was not properly epoxied. Rebar came loose from embedment points with a hit of the hammer. Check epoxy at next inspection.

 07/03/2023FRAMINGJoseph RobinsonDISAPPROVED6/29/2023 3:39:43 PM ST 7/3/2023 2:00:23 PM Door locked. No access.

 07/07/2023TIE BEAM/BONDJoseph RobinsonAPPROVEDFor Openings7/7/2023 2:16:33 PM Tie Beam over openings approved.

 07/07/2023SLABJoseph RobinsonDISAPPROVED7/7/2023 2:17:48 PM Not ready for inspection.

 07/11/2023FRAMINGAnthony CrisantiPARTIAL APPROVAL7/10/2023 10:13:42 AM ST 7/11/2023 1:19:37 PM Partial on the roof framing for the pilasters. (See Below) Was shown the new revisions from engineered also saw inside each form. (New material for wood, steel gage and anchor system). Patrial based on submission of revisions to city Also informed that rail at end needs gap closed in.

 07/13/2023WIND/DOOR BUCKAnthony CrisantiDISAPPROVED7/12/2023 9:41:42 AM an 7/13/2023 10:33:14 AM Not ready schedule for tomorrow

 07/14/2023WIND/DOOR ATTACHMENTWyatt T. HaygoodCANCELLED BY PERMITE7/14/2023 8:19:22 AM MT-CX BY ANDRES

 07/14/2023WIND/DOOR BUCKWyatt T. HaygoodCANCELLED BY PERMITE7/14/2023 8:19:47 AM MT-CX BY ANDRES

 07/14/2023DEMO STRUCTURALWyatt T. HaygoodAPPROVED

 07/14/2023SLABWyatt T. HaygoodAPPROVED7/13/2023 2:52:52 PM FM 7/14/2023 12:46:01 PM Patio slab

 07/18/2023WIND/DOOR BUCKJoseph RobinsonAPPROVED7/17/2023 9:41:31 AM ST

 07/18/2023WIND/DOOR ATTACHMENTJoseph RobinsonPARTIAL APPROVALSEE NOTES7/14/2023 12:44:13 PM See Permit # 2303-0096 for window and door product approvals and plan review 7/17/2023 9:42:25 AM ST 7/17/2023 9:42:37 AM wth 7/18/2023 11:11:00 AM Ok to install all openings.

 07/21/2023WIND/DOOR ATTACHMENTWyatt T. HaygoodPARTIAL APPROVAL7/20/2023 8:07:29 AM FM 7/21/2023 2:52:52 PM All windows and doors approved except new door opening on east exterior wall.

 07/24/2023FIRE SPRINKLER ROUGHDaniel ChavezPARTIAL APPROVAL7/21/2023 12:26:11 PM JS 7/24/2023 9:40:30 AM Kitchen area rough for uprights

 07/28/2023TRUSS PLANS ON FILEWyatt T. HaygoodAPPROVEDSUBMITTED

 07/31/2023ROOF SHEATHINGTony WillsonDISAPPROVED7/28/2023 9:35:54 AM MT 7/31/2023 4:20:11 PM No OSHA approved ladder to be able to gain access to the roof sheathing. Only A-Frame Ladders and (1) Extension Ladder that wasn't tall enough to reach from the ground to 3' above the roof line.

 07/31/2023TRUSSTony WillsonDISAPPROVED7/31/2023 4:34:43 PM Trusses were missing engineering based on the approved set onsite. Any lateral Braced engineering can be substituted for a T-Brace or Scab Brace if the lateral brace isn't going to work because of truss webs.

 08/01/2023TRUSSAlejandro CorralesCANCELLED BY PERMITEMissing Lateral Bracing & Truss Repairs?

 08/01/2023ROOF SHEATHINGAlejandro CorralesAPPROVEDOSHA Approved Ladder Needed.

 08/01/2023WALL SHEATHINGAlejandro CorralesAPPROVED

 08/16/2023TIN CAPAlejandro CorralesDISAPPROVED8/15/2023 2:42:23 PM wth 8/16/2023 3:38:45 PM Unsafe ladder set up off of the scaffolding. Ladder is not strapped.

 08/16/2023HOT MOP IN PROGRESSAlejandro CorralesDISAPPROVED8/15/2023 2:44:47 PM wth 8/16/2023 3:38:47 PM Unsafe ladder set up off of the scaffolding. Ladder is not strapped. After tin cap approval, complete the peel and stick 100 percent and reschedule hot mop inspection separately.

 08/17/2023FIRE SPRINKLER ROUGHDaniel ChavezPARTIAL APPROVAL8/16/2023 2:09:47 PM MT 8/17/2023 2:25:27 PM Bar area and outside seating rough sprinklers with pressure test done

 08/17/2023TIN CAPJoseph RobinsonAPPROVED

 08/18/2023ROOF IN PROGRESSWyatt T. HaygoodAPPROVED

 08/22/2023ROUGH DUCTDave Chin-SangDISAPPROVED8/21/2023 10:38:25 AM VB 8/22/2023 10:51:22 AM Metal ductwork sizes not to plan , additional supports needed unless strap thickness proves otherwise. Change of plan for duct sizes and termination location required before cover.

 08/22/2023ROOF IN PROGRESSJoseph RobinsonAPPROVED8/21/2023 8:46:55 AM wth

 08/23/2023WIRE LATHAlejandro CorralesAPPROVED8/22/2023 2:46:31 PM vb

 08/23/2023ROOF IN PROGRESSAlejandro CorralesPARTIAL APPROVAL8/23/2023 4:24:13 PM Col-180 base complete on rear deck. Torchdown cap sheet in progress. TPO complete on kitchen deck roof. Flashing in progress.

 08/24/2023ROOF IN PROGRESSAlejandro CorralesPARTIAL APPROVAL8/24/2023 12:44:23 PM 1) Kitchen deck TPO and flashing complete - Final in this area is approved. 2) Bar deck and walkway Conv. 180 complete. Flan 180 torchdown cap sheet at bar deck complete. Flan 180 torchdown at walkways in progress. See map for progress and locations

 08/28/2023ROOF IN PROGRESSJoseph RobinsonAPPROVED

 08/29/2023TRUSSJoseph RobinsonAPPROVED8/28/2023 11:52:59 AM FM

 08/30/2023TOP OUTJeremy HassenplugPARTIAL APPROVALSEE NOTES8/29/2023 10:05:01 AM VB FOR KITCHEN SANITARY WATER PIPING 8/30/2023 11:43:52 AM Partial for kitchen top out only good. Hot water recirculation line needs to be insulated.

 09/01/2023ELEC WALL ROUGHJoe NievesAPPROVED8/31/2023 2:56:07 PM MT

 09/05/2023GAS LINE RGH IN-PLJan TranaDISAPPROVED8/31/2023 11:52:21 AM MT 9/5/2023 10:56:47 AM No test

 09/06/2023GAS LINE RGH IN-PLJan TranaDISAPPROVED9/5/2023 11:36:29 AM FM 9/6/2023 12:22:57 PM Low line pressure

 09/06/2023ELEC CEILING ROUGHJoe NievesAPPROVED9/5/2023 1:51:28 PM JS 9/6/2023 12:55:55 PM ELECTRIC CEILING ROUGH FOR [OUTSIDE PATIO AREA]

 09/06/2023ELECTRIC ROUGHJoe NievesAPPROVED9/6/2023 1:02:38 PM ELECTRIC ROUGH APPROVED FOR [ATTIC AREA/ ABOVE KITCHEN]

 09/06/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALLight test9/6/2023 1:40:28 PM 16' 22" x 16" Horizontal type 1 duct approved to wrap 1 of 2 Type 1 riser through curb approved to wrap.

 09/06/2023ROUGH DUCTDave Chin-SangCANCELLED BY DEPT9/5/2023 3:24:34 PM FM

 09/06/2023FRAMINGJoseph RobinsonDISAPPROVED9/5/2023 1:50:55 PM JS 9/6/2023 2:31:31 PM Provide attachment detail for studs to exterior wall. Provide detail for metal stud gauge. Seal all penetrations in exterior walls.

 09/06/2023ROUGH FIRE SPRINKLERDaniel ChavezDISAPPROVED9/6/2023 2:48:25 PM a head needs to be added to the rear entrance, the wait station and elbow and correct head have to be replaced at entrance to kitchem .preasure test is needed and plans resubmission to show tis changes.

 09/07/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVAL9/6/2023 3:32:42 PM FM

 09/07/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALLight test9/7/2023 9:33:42 AM Light test for 2 risers going in curb, approved to wrap.

 09/07/2023GAS LINE RGH IN-PLJan TranaPARTIAL APPROVAL9/6/2023 12:45:39 PM vb 9/7/2023 12:28:17 PM Above ceiling only

 09/07/2023ELECTRIC ROUGHRinor KrasniqiPARTIAL APPROVALwall rough9/6/2023 12:46:58 PM vb 9/7/2023 2:47:35 PM Wall rough kitchen pass

 09/08/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL1st layer wrap9/8/2023 12:29:06 PM 1st layer approved to do 2nd layer 9/8/2023 12:30:25 PM Approved to do 2nd layer

 09/08/2023TOP OUTJan TranaAPPROVED9/7/2023 2:30:41 PM FM

 09/08/2023FRAMINGWyatt T. HaygoodAPPROVED9/7/2023 10:56:40 AM ST 10/6/2023 12:51:34 PM framing complete

 09/11/2023INSULATIONWyatt T. HaygoodPARTIAL APPROVAL9/8/2023 3:00:24 PM MT 9/11/2023 12:59:21 PM Walls only Need Columns on Exterior Walls and Ceiling in Kitchen Areas to complete this inspection category.

 09/11/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL2nd layer wrap9/11/2023 1:09:08 PM 2nd layer wrap approved ok to install vertical risers in roof curbs

 09/12/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVAL9/12/2023 1:16:37 PM 20x12 North trunk by bar, ok to wrap, 40x10 main ok to wrap S bar not to approved plan 14x10 on plan 12x10 ran.

 09/13/2023INSULATIONWyatt T. HaygoodPARTIAL APPROVAL9/11/2023 2:33:18 PM ST 9/13/2023 10:13:05 AM wall insulation complete need ceiling insulation in kitchen area to complete this inspection category.

 09/14/2023ROUGH FIRE SPRINKLERDaniel ChavezAPPROVED

 09/15/2023INSULATIONWyatt T. HaygoodAPPROVED9/15/2023 11:40:43 AM wth

 09/18/2023FIRE ALARM ROUGH ELJoe NievesAPPROVED9/15/2023 2:10:12 PM FM

 09/19/2023SECOND ROUGHJan TranaCANCELLED BY PERMITERAINWATER9/18/2023 8:10:43 AM VB

 09/19/2023FIRE ALARM FIREDaniel ChavezPARTIAL APPROVALFIRE ALARM ROUGH FIRE9/18/2023 11:55:05 AM VB PLEASE CONTACT (954)785-7800 9/19/2023 10:58:27 AM verified device locations as per plans for new addition. 11/30/2023 5:17:38 PM Gas detection system needs to be tested with full fire alarm test. 11/30/2023 Capt L. Merritt

 09/19/2023ELECTRIC ROUGHJoe NievesAPPROVEDCEILING ROUGH9/18/2023 8:12:36 AM VB

 09/20/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVALTake off dampers COP required for final9/19/2023 3:46:47 PM FM 9/20/2023 11:41:20 AM Main dining room and bar area rough duct approved to cover pending cop for removal of take off damper . Private dining has no damper's also

 09/20/2023DRYWALL SCREWJoseph RobinsonPARTIAL APPROVAL9/20/2023 2:31:44 PM Partial for walls. See map.

 09/22/2023RAIN WATER FINALJan TranaAPPROVED9/21/2023 11:24:45 AM FM

 09/26/2023LOW VOLTAGE ROUGHJoe NievesAPPROVED9/25/2023 9:37:00 AM VB 9/26/2023 10:39:25 AM LOW VOLTAGE CEILING ROUGH APPROVED/ SYSTEMS APPROVED/ CAMERAS, SPEAKERS, TV CABLE. PRIVATE DINING DINING AREA BAR AREA

 10/06/2023DRYWALL SCREWWyatt T. HaygoodAPPROVED10/5/2023 9:04:12 AM VB 10/6/2023 12:31:46 PM Drywall complete for all areas including interior walls and ceilings and exterior ceiling at Lania areas

 10/06/2023WIND/DOOR ATTACHMENTWyatt T. HaygoodAPPROVED10/6/2023 12:35:18 PM windows and doors complete

 10/06/2023HOT MOP IN PROGRESSWyatt T. HaygoodAPPROVED10/6/2023 12:36:57 PM cap sheet complete

 10/06/2023SIDEWALK FORMSWyatt T. HaygoodAPPROVED10/6/2023 12:50:13 PM concrete patio deck at rear of building

 10/09/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVAL10/6/2023 11:46:33 AM FM 10/9/2023 9:29:03 AM DOAS duct reduced at transition from 26 x16 to 26 x13 approx 4' @ main supply at elbow in building. Then goes back to 26 x 16. 26x16 make up air to hood approved to wrap

 10/09/2023ROOF IN PROGRESSJoseph RobinsonAPPROVED10/6/2023 9:46:23 AM FM

 10/12/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVAL10/11/2023 10:45:50 AM FM 10/12/2023 11:10:55 AM Unable to inspect due to floor work being done.

 10/13/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVALDOAS Ductwork10/13/2023 9:54:41 AM 26x16 supply @Curb corrected approved to wrap.

 10/17/2023EXHAUST HOOD ROUGHDave Chin-SangDISAPPROVED10/17/2023 9:04:29 AM Type 1 duct ability to store grease @ elbow to roof curb. See photo No access to electrical junction box on top of hood. Unable to inspect due to no access. Duct should be tested before installation.

 10/17/2023UNIT MASONRY CERTBill TracyAPPROVED10/17/2023 2:05:13 PM UNIT MASONRY CERTIFICATION SUBMITTED FROM ECS FLORIDA, LLC

 10/17/2023ROOF FINALJoseph RobinsonDISAPPROVED10/17/2023 4:22:27 PM Complete roof drains. Work incomplete.

 10/18/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL10/17/2023 12:54:07 PM VB 10/18/2023 9:53:53 AM Light test type 1 duct on ground. Approved to install. Spoke to Andres and Advance about 1/4" /ft pitch for duct towards hood. Spoke about 18" clearance from exhaust fan and combustible roof material.

 10/18/2023CONSULTATIONJoe NievesAPPROVED

 10/19/2023ROOF FINALTony WillsonAPPROVED10/19/2023 7:26:19 AM Flat & Slope Roofs.

 10/20/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL10/19/2023 12:58:36 PM MT 10/20/2023 2:08:46 PM Light test duct for new hood approved to wrap

 10/24/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALLIGHT TEST10/23/2023 4:02:50 PM VB 10/24/2023 10:28:40 AM Horizontal section installed up to 1st intake from hood approved to wrap

 10/25/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL10/24/2023 4:27:44 PM MT 10/25/2023 12:40:36 PM Bottom joint between existing hood exhaust left to right not ready for inspection

 10/26/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL10/25/2023 4:38:04 PM vb 10/26/2023 11:33:08 AM Old hood duct approved to wrap

 10/26/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALLIGHT TEST FOR HOOD10/26/2023 7:22:43 AM ST 10/26/2023 11:33:10 AM Old hood duct approved to wrap.

 10/26/2023CEILING GRIDJoseph RobinsonPARTIAL APPROVAL10/25/2023 2:02:03 PM FM 10/26/2023 12:44:03 PM Pending kitchen.

 10/27/2023EXHAUST HOOD ROUGHDave Chin-SangDISAPPROVED - FEE10/26/2023 3:32:10 PM FM 10/27/2023 12:29:52 PM 2 leaks on new hood exhaust

 10/30/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL10/27/2023 2:25:35 PM FOR LIGHT TEST 10/30/2023 12:26:33 PM New hood exhaust approved to cover

 11/02/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALOven LIGHT TEST REQUESTED11/1/2023 12:14:16 PM JS 11/2/2023 11:46:05 AM Curb down round duct for Oven approved to wrap . approximately 4'

 11/03/202330 DAY FOR TESTINGJoe NievesAPPROVED11/2/2023 2:43:11 PM MT 11/3/2023 9:54:16 AM OK TO ENERGIZE PANELS/ LKC LKC-1 LKC-2

 11/03/2023TEMP ON HOUSEJoe NievesAPPROVED11/2/2023 2:43:27 PM MT 11/3/2023 9:54:17 AM OK TO ENERGIZE PANELS/ LKC LKC-1 LKC-2

 11/03/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALAccess doors light test

 11/03/2023ROUGH DUCTDave Chin-SangCANCELLED BY DEPTincorrect inspection11/2/2023 2:35:46 PM MT

 11/06/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVAL2nd layer

 11/06/2023ROUGH DUCTDave Chin-SangCANCELLED BY DEPT

 11/07/2023ELECTRIC ROUGHRinor KrasniqiDISAPPROVED - FEE11/6/2023 12:59:44 PM FM 11/7/2023 3:14:15 PM Kitchen ceiling disapproved 330.30 secure MC within 12" of junction and 6' thereafter 300.6 armored cable shall be protected from corrosion and deterioration, kept from dissimilar metals. Mc sheathing is aluminum, sprinkler conduit is cast iron. cast iron will deteriorate aluminum

 11/07/2023CEILING GRIDTony WillsonDISAPPROVED11/6/2023 9:04:20 AM mt 11/7/2023 3:52:21 PM Incomplete.

 11/08/2023GAS LINE RGH IN-PLJan TranaAPPROVED11/6/2023 2:39:50 PM FM

 11/08/2023EXHAUST HOOD ROUGHDave Chin-SangPARTIAL APPROVALPENDING COP for ENTIRE SYSTEM11/7/2023 1:58:28 PM FM

 11/08/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVALDOAS11/8/2023 11:33:21 AM Flex duct needs to be supported maximum 4' apart

 11/08/2023CEILING GRIDTony WillsonAPPROVED11/7/2023 4:22:40 PM MT

 11/09/2023SEWER CONNECTIONJan TranaAPPROVED11/8/2023 12:50:50 PM JS

 11/09/2023ROUGH DUCTDave Chin-SangPARTIAL APPROVALDOAS in kitchen

 11/09/2023ELECTRIC ROUGHJoe NievesAPPROVED11/8/2023 2:47:07 PM MT 11/9/2023 11:08:21 AM ELECTRIC CEILING ROUGH [NEW KITCHEN] APPROVED.

 11/16/2023FINAL FIRE SPRINKThomas HayesPARTIAL APPROVAL11/15/2023 2:11:22 PM JS 11/16/2023 3:21:50 PM ONE EXISTING HEAD NEAR CRESCENT/CIRCULAR AREA BLOCKED BY SHELVING THAT WAS PUT IN AFTER THE FACT ONE NEW HEAD TO EAST OF BAR MISSING CONCEAL CAP ONE NEW HEAD IN KITCHEN STORAGE MISSING CONCEAL CAP *** IF PARKLAND BUILDING DEPARTMENT ALLOWS, THIS MAY BE CALLED IN TO BE CONDUCTED IN TANDEM WITH THE FINAL FIRE PERMIT ***

 11/29/2023DECK STEEL/PAVERSAnthony CrisantiAPPROVED11/28/2023 8:32:25 AM FM 11/29/2023 7:46:55 AM 11-2

 11/30/2023SMOKE DETECTOR TESTScott WieselCANCELLED BY DEPT11/30/2023 11:51:45 AM Out of sequence duct rough first

 11/30/2023FIRE SUPP TESTScott WieselCANCELLED BY DEPT11/29/2023 12:10:46 PM FM 11/30/2023 11:51:46 AM Out of sequence

 11/30/2023FIRE ALARM FINAL ELPedro VieiraPARTIAL APPROVAL11/30/2023 12:44:53 PM Inspector EL12 changed the inspection assignment from EL12 to EL16 11/30/2023 1:46:04 PM Was not able to test any emergency circuits. Preferably to test when mechanical, fire department and electrical do all on the same day together.

 11/30/2023FINAL GAS-FIRELici MerrittAPPROVEDSEE NOTES6/8/2023 10:41:16 AM DO NOT SCHEDULE AS SAME DAY OF FIRE DETECTION. GAS DETECTION SHUTOFF SYSTEM PER BROWARD COUNTY AMENDMENT. 11/30/2023 5:19:18 PM Gas detections system to be tested with fire alarm. 11/30/2023 Capt. Lici Merritt

 12/01/2023ROUGH DUCTScott WieselAPPROVED11/30/2023 12:04:16 PM FM

 12/01/2023EXHAUST HOOD ROUGHScott WieselAPPROVED11/30/2023 12:04:30 PM FM

 12/05/2023FINAL GAS-PLUMBINGJan TranaAPPROVED12/4/2023 12:47:52 PM vb

 12/05/2023SECOND ROUGHJan TranaAPPROVED12/4/2023 12:57:53 PM vb

 12/06/2023PIPE MATERIALPerry TabornAPPROVED12/5/2023 11:13:54 AM FM

 12/06/2023EXHAUST ROUGHDave Chin-SangPARTIAL APPROVAL12/5/2023 2:13:35 PM FM 12/6/2023 9:57:48 AM Pizza oven exhaust duct connection above oven to penetration light test

 12/07/2023EXHAUST ROUGHDave Chin-SangAPPROVED12/6/2023 11:21:30 AM FM 12/7/2023 9:14:01 AM Fire wrap approved.

 12/12/2023FIRE SPRINKLER FINALThomas HayesAPPROVED12/11/2023 2:06:08 PM vb

 12/15/2023SEWER FINALJan TranaAPPROVED12/14/2023 2:13:47 PM FM

 12/15/2023PLUMBING FINALJan TranaDISAPPROVED12/14/2023 2:14:09 PM FM 12/15/2023 10:02:16 AM No water volume to south sinks

 12/15/2023PLUMBING FINALJan TranaAPPROVED

 12/15/2023LOW VOLTAGE FINALRinor KrasniqiDISAPPROVEDADD CAM,SPKS,WIFI12/14/2023 2:04:31 PM MT 12/15/2023 2:53:03 PM BCA 110.9 Work not complete missing cameras 107.3 Provide approved legible plan 107.3 Provide GC letter raised floor box to be covered by station NEC 640.22 Provide bonding conductor to rack

 12/19/2023ZONING INSPECTIONKEITH & ASSOCAPPROVED12/14/2023 2:14:26 PM FM

 12/21/2023EXHAUST HOOD FINALDave Chin-SangPARTIAL APPROVAL9/8/2023 2:59:52 PM MT 12/21/2023 10:23:26 AM Need to verify hi-them gasket

 12/21/2023SMOKE DETECTOR TESTDave Chin-SangAPPROVED12/20/2023 12:14:31 PM ST

 12/21/2023FIRE SUPP TESTDave Chin-SangDISAPPROVED12/20/2023 12:14:10 PM ST 12/21/2023 10:23:29 AM Gas leak. Test wasn't performed

 12/21/2023MECHANICAL FINALDave Chin-SangDISAPPROVED12/20/2023 12:17:00 PM ST 12/21/2023 10:23:31 AM Pizza oven exhaust model number doesn't match. Condensate line needs pitch on roof

 12/21/2023LOW VOLTAGE FINALJoe NievesDISAPPROVED12/20/2023 12:14:56 PM ST 12/21/2023 10:47:04 AM EQUIPMENT BONDING CONNECTION REQUIRED/ I/T LOW VOLTAGE RACK LOW VOLTAGE CABLING TERMINATIONS/COMPLETED LOW VOLTAGE RACK CAMERA MONITOR REQUIRED WORK NOT COMPLETED/ FBC 110.9.1

 12/21/2023FIRE ALARM FINAL ELJoe NievesDISAPPROVED12/19/2023 10:26:00 AM FM 12/20/2023 2:22:57 PM CANCELLED 12/20/2023 3:58:44 PM JS 12/21/2023 10:47:06 AM GAS DETECTION/HOOD SYSTEM FAILED FIRE ALARM PLAN/AS-BUILT REQUIRED/FBC 107.1 FIRE ALARM DEVICE LABELS REQUIRED

 12/21/2023ELECTRIC FINALJoe NievesPARTIAL APPROVAL12/19/2023 9:53:24 AM FM 12/21/2023 10:47:08 AM PRINTED PANEL LEGENDS REQUIRED/NEC 408.4 PROTECT S/O CABLE ROOFTOP FAN UNITS/NEC 110.3 B SUPPORT REQUIRED FOR FLEX USED ON ROOFTOP FAN UNITS/ NEC 110.3 B FAILED EXIT LIGHTING UNITS KITCHEN/DINING AREAS/ CHECK ALL UNITS/ NEC 700 120 VOLT RECEPTACLES IN KITCHEN/DISHWASHING ARES REQUIRE GFCI PROTECTION/ NEC 210

 12/21/2023SMOKE DETECTOR TESTLici MerrittAPPROVED12/21/2023 8:48:07 AM JS

 12/21/2023FIRE ALARM FIRELici MerrittDISAPPROVEDFINAL FIRE ALARM12/21/2023 2:04:59 PM Gas detection system needs testing again; not All devices worked properly. A gas shutoff solenoid needs to be provided. Label the f/a panel for devices 68, 69, 73. Revision required for the plans because they did no work in the lobby, and plans show added devices. CAPTAIN LICI MERRITT AMERRITT@CORALSPRINGS.GOV

 12/21/2023FIRE SUPP TESTLici MerrittDISAPPROVEDFire Dept11/16/2023 3:40:07 PM SPOKE WITH ANDRES ABOUT PUTTING WHEEL CHOCKS AND TETHER FOR EACH COOKING APPLIANCE 12/21/2023 2:09:30 PM POSSIBLE GAS LEAK. INSPECTION NOT PERFORMED. CAPTAIN LICI MERRITT AMERRITT@CORALSPRINGS.GOV

 12/22/2023FINAL SURVEYBill TracyAPPROVED12/22/2023 3:20:55 PM FINAL SURVEY - NO ELEVATION CERTIFICATE. X ZONE

 01/09/2024MECHANICAL FINALDave Chin-SangAPPROVED1/8/2024 9:41:49 AM VB

 01/09/2024EXHAUST HOOD FINALDave Chin-SangAPPROVED1/8/2024 12:19:09 PM VB

 01/09/2024FIRE SUPP TESTDave Chin-SangAPPROVED1/2/2024 11:30:22 AM FM

 01/09/2024FIRE ALARM FINAL ELRinor KrasniqiAPPROVED1/8/2024 2:47:06 PM ST

 01/09/2024ELECTRIC FINALRinor KrasniqiDISAPPROVED1/8/2024 4:28:43 PM VB 1/9/2024 1:26:18 PM Work not to plan 110.9 GFCI readily accessible 210.8 GFCI protect receptacles 150v or less to ground 100 amps or less in kitchens and within 6' of sinks top edge 210.8 (B) Plan asking for metallic in use covers in kitchen 406.9

 01/09/2024FIRE SUPP TEST-FIREBruno MatosAPPROVED1/8/2024 4:29:53 PM VB

 01/09/2024FIRE ALARM FIREBruno MatosAPPROVEDFINAL FIRE ALARM1/8/2024 2:54:22 PM ST

 01/10/2024FINAL INSPECT-FIREThomas HayesAPPROVED11/16/2023 3:24:29 PM SEE FIRE SPRINKLER NOTES FROM 11/16/2023 (TH) SPOKE WITH ANDRES ABOUT POSSIBLE NEED FOR EXTINGUISHER BETWEEN ONE AT WEST SIDE OF THE BAR AND THE OTHER AT THE EXIT OF THE PRIVATE DINING ROOM AREA. SPOKE WITH ANDRES ABOUT THE CLASS K EXTINGUISHER PLACEMENT. SPOKE WITH ANDRES ABOUT THE NEED FOR BOTH TETHERS AND WHEEL CHOCKS FOR ALL COOKING APPLIANCES UNDER THE HOOD. 1/9/2024 3:05:48 PM FM

 01/10/2024ELECTRIC FINALJoe NievesAPPROVED1/9/2024 3:28:46 PM ST

 01/10/2024LOW VOLTAGE FINALJoe NievesAPPROVED1/9/2024 3:29:15 PM ST

 01/11/2024FINALJoseph RobinsonAPPROVED1/10/2024 12:04:09 PM MT 1/11/2024 3:35:01 PM Approved by BD26.

 01/16/2024ADMIN CHECKLIST**Bill TracyAPPROVED1/16/2024 11:42:12 AM FINAL TERMITE SUBMITTED