Permit No. BLDG2309-0084 Permit Type   SCR POOL/PORCH Site Address   6726 NW 80 MNR
PARKLAND, FL 330672488
Applied   09/11/2023 Applicant  
Approved   09/12/2023 Owner   OH,RAQUEL D & STEPHEN
Issued   09/21/2023 Contractor   R & S ASSEMBLY LLC DBA SCREEN BUILDERS
Parent Permit No.   Description   POOL SCREEN ENCLOSURE W/ FOOTER
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 11/28/2023NOCFelicia MullenAPPROVED

 11/29/2023FOOTER BONDPedro VieiraDISAPPROVED11/28/2023 4:06:14 PM JS 11/29/2023 10:50:42 AM Footer steel bar shall be connected to equipotential bond. Contractor left a wire stubbed up for column bond but did not make connection from equipotential bond to footer steel.

 11/29/2023FOOTER/FOUNDATIONJoseph RobinsonAPPROVED12X12 W/1 #511/28/2023 4:06:27 PM JS

 12/04/2023FOOTER BONDJoe NievesDISAPPROVEDeTRAKiT Inspection Request12/1/2023 1:59:02 PM 12/1/2023 1:59 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM 12/4/2023 1:38:21 PM THE [EQUIPOTENTIAL BONDING CONDUCTOR] MUST BE PROTECTED FROM DAMAGE WITHIN ITS [ENTIRE] LENGTH TERMINATING AT THE EQUIPMENT PAD. THE USE OF SCHEDULE 80 PVC [MUST] BEUSED TO PROTECT BOND CONDUCTOR. A SHORT LENGTH OF BONDING CONDUCTOR MUST BE INSTALLED FROM STEEL TO SCREEN ENCLOSURE FRAME. ALL WORK MUST BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. NEC 300.4 NEC 110.12 NEC 300.5

 12/12/2023FOOTER BONDRinor KrasniqiDISAPPROVEDeTRAKiT Inspection Request12/11/2023 3:59:03 PM 12/11/2023 3:59 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM 12/12/2023 12:39:14 PM 300.5 pvc raceway shall be buried 18" Or 24" for single conductor Easy fix just direct connect to copper conductor around the pool with DB split bolt

 12/13/2023FOOTER BONDJoe NievesDISAPPROVEDeTRAKiT Inspection Request12/12/2023 4:14:02 PM 12/12/2023 4:14 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS THERE IS A PIPE BURIED A FEW INCHES DOWN. THE 2ND INSPECTOR MET WITH OUR CONCRETE GUY AND TOLD HIM WHAT NEEDED TO BE DONE. HE DID WHAT HE WAS TOLD TO DO Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM 12/13/2023 9:59:42 AM Inspector EL18 changed the inspection assignment from EL18 to EL12 12/13/2023 2:54:10 PM WORK NOT COMPLETE/FBC110.9.1

 12/18/2023FOOTER BONDJoe NievesAPPROVED

 02/05/2024SCREEN BONDPedro VieiraAPPROVEDeTRAKiT Inspection Request2/2/2024 3:58:28 PM 2/2/2024 3:58 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM

 02/05/2024SAFETY ACT 515Joseph RobinsonAPPROVEDeTRAKiT Inspection Request2/2/2024 3:58:36 PM 2/2/2024 3:58 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM

 02/06/2024FINAL**Joseph RobinsonAPPROVEDeTRAKiT Inspection Request2/5/2024 1:10:10 PM 2/5/2024 1:10 PM R & S ASSEMBLY LLC DBA SCREEN BUILDERS Contact Name: R & S ASSEMBLY LLC DBA SCREEN BUILDERS Site Address: 6726 NW 80 MNR Phone: 5617936029 e-Mail: PERMITS@SCREENBUILDERSINC.COM