05/27/2020 | PRODUCT APPROVALS | Wyatt T. Haygood | APPROVED | | |
|
05/27/2020 | TRUSS PLANS ON FILE | Wyatt T. Haygood | APPROVED | | |
|
06/30/2020 | SOIL BEARING CERT | Bill Tracy | APPROVED | | 6/30/2020 10:15:37 AM
STATEMENT OF SOIL BEARING FROM UNIVERSAL ENGINEERING, WITH BORING LOG AND DENSITIES, ATTESTING TO A BEARING CAPACITY OF 2500 PSF
|
|
06/30/2020 | NOC | Debbie Grosse | APPROVED | | |
|
12/17/2020 | WATER SERVICE | Scott Wiesel | APPROVED | | 12/16/2020 3:18:21 PM
JS
|
|
12/17/2020 | SEWER CONNECTION | Scott Wiesel | APPROVED | | 12/16/2020 3:18:09 PM
JS
|
|
12/17/2020 | CONDENSATE LINE | Scott Wiesel | APPROVED | | 12/16/2020 3:17:57 PM
JS
|
|
12/17/2020 | GROUND ROUGH | Scott Wiesel | APPROVED | | |
|
12/22/2020 | SOIL TERMITE TREAT | Wyatt T. Haygood | APPROVED | | |
|
12/23/2020 | NPDES INITIAL | Perry Taborn | APPROVED | eTRAKiT Inspection Request | 12/22/2020 3:45:03 PM
12/22/2020 3:45 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
12/23/2020 | SLAB ELECTRIC | Carmen Di Paula | APPROVED | | 12/22/2020 4:37:13 PM
ST
|
|
12/23/2020 | SERVICE GROUND | Carmen Di Paula | APPROVED | | 12/22/2020 4:36:52 PM
ST
|
|
12/23/2020 | SLAB | Wyatt T. Haygood | APPROVED | | 12/23/2020 10:43:40 AM
wth
|
|
01/14/2021 | SPOT SURVEY | Wyatt T. Haygood | APPROVED | | |
|
01/15/2021 | TIE BEAM/BOND | Wyatt T. Haygood | PARTIAL APPROVAL | | 1/15/2021 8:00:40 AM
wth
1/15/2021 2:21:29 PM
Windows on left hand side of home not as per plan.
Transom window over entry door not on plan.
Contractor can pour at own risk.
Change of plan required.
|
|
01/28/2021 | ROOF SHEATHING | Alejandro Corrales | APPROVED | | 1/27/2021 3:19:22 PM
wth
|
|
02/09/2021 | TUB ROUGH-IN | Jeremy Hassenplug | APPROVED | | 2/8/2021 2:00:45 PM
ST
|
|
02/09/2021 | TOP OUT | Jeremy Hassenplug | APPROVED | CHECK FIXTURES LOCATION | 2/8/2021 2:01:17 PM
ST
|
|
02/09/2021 | SHOWER PAN | Jeremy Hassenplug | APPROVED | | 2/8/2021 2:00:15 PM
ST
|
|
02/09/2021 | SECOND ROUGH | Jeremy Hassenplug | APPROVED | | 2/8/2021 1:59:48 PM
ST
|
|
02/09/2021 | TRUSS | Alejandro Corrales | DISAPPROVED | | 2/8/2021 3:09:06 PM
ST
2/9/2021 4:43:49 PM
Trusses C4, C9 and B3(2) hangers on one side need to be replaced. Currently the hangers don't have slant nails installed. Trusses do not sit fully into the truss hangers. Replace a total of 4 truss hangers for ones with the same or greater uplift with through-nails.
|
|
02/11/2021 | TRUSS | Joseph Robinson | APPROVED | eTRAKiT Inspection Request | 2/10/2021 3:41:53 PM
2/10/2021 3:41 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
02/12/2021 | TIE BEAM/BOND | Wyatt T. Haygood | APPROVED | | 2/12/2021 8:31:15 AM
wth
|
|
02/12/2021 | WIND/DOOR BUCK | Wyatt T. Haygood | APPROVED | | 2/12/2021 8:31:51 AM
wth
|
|
02/17/2021 | UNIT MASONRY CERT | Bill Tracy | APPROVED | | 2/17/2021 3:52:01 PM
UNIT MASONRY CERTIFICATION FROM SPECIALTY ENGINEERING
|
|
02/23/2021 | WALL SHEATHING | Wyatt T. Haygood | APPROVED | eTRAKiT Inspection Request | 2/23/2021 5:54:24 AM
2/23/2021 5:54 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
2/23/2021 5:54:37 AM
2/23/2021 5:54 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
02/25/2021 | TIN CAP | Wyatt T. Haygood | APPROVED | | |
|
03/09/2021 | ROUGH DUCT | Dave Chin-Sang | DISAPPROVED | eTRAKiT Inspection Request | 3/8/2021 6:24:48 AM
3/8/2021 6:24 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/9/2021 11:58:57 AM
Missing return in office
|
|
03/09/2021 | GAS LINE RGH IN-PL | Dave Chin-Sang | DISAPPROVED | eTRAKiT Inspection Request | 3/8/2021 6:25:50 AM
3/8/2021 6:25 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/9/2021 11:59:01 AM
Line losing pressure
|
|
03/09/2021 | EXHAUST ROUGH | Dave Chin-Sang | DISAPPROVED | eTRAKiT Inspection Request | 3/8/2021 6:25:13 AM
3/8/2021 6:25 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/9/2021 11:59:04 AM
Dryer vent needs stud guard.
|
|
03/09/2021 | ELECTRIC ROUGH | Joe Nieves | APPROVED | eTRAKiT Inspection Request | 3/8/2021 6:25:32 AM
3/8/2021 6:25 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
03/09/2021 | HOT MOP IN PROGRESS | Alejandro Corrales | DISAPPROVED | eTRAKiT Inspection Request | 3/8/2021 6:26:14 AM
3/8/2021 6:26 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/9/2021 5:05:15 PM
No Ladder on site
|
|
03/10/2021 | TEMP ON HOUSE | Joe Nieves | APPROVED | eTRAKiT Inspection Request | 3/9/2021 7:39:27 PM
3/9/2021 7:39 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
03/10/2021 | GAS LINE RGH IN-PL | Dave Chin-Sang | DISAPPROVED | eTRAKiT Inspection Request | 3/9/2021 4:00:04 PM
3/9/2021 4:00 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/10/2021 1:59:43 PM
1/2" tee feeding 2nd dryer needs to be replaced to 3/4" tee
COP required for added 2nd drier
1/2" tee feeding cook top incorrect.
|
|
03/10/2021 | EXHAUST ROUGH | Dave Chin-Sang | DISAPPROVED - FEE | eTRAKiT Inspection Request | 3/9/2021 3:58:05 PM
3/9/2021 3:58 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/10/2021 1:59:48 PM
2nd inspection. Separate electrical wire from dryer exhaust duct.
Shield plates required FBC Res / M 1502.5
|
|
03/10/2021 | ROUGH DUCT | Dave Chin-Sang | APPROVED | eTRAKiT Inspection Request | 3/9/2021 3:58:38 PM
3/9/2021 3:58 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
03/10/2021 | HOT MOP IN PROGRESS | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 3/9/2021 7:35:21 PM
3/9/2021 7:35 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
03/11/2021 | EXHAUST ROUGH | Dave Chin-Sang | APPROVED | eTRAKiT Inspection Request | 3/10/2021 7:24:26 PM
3/10/2021 7:24 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
03/23/2021 | LOW VOLTAGE ROUGH | Joe Nieves | APPROVED | TV,PHONE,WIFI | 3/22/2021 7:48:59 AM
JS
|
|
03/23/2021 | WIND/DOOR ATTACHMENT | Alejandro Corrales | APPROVED | | 3/22/2021 4:00:06 PM
VB
|
|
03/24/2021 | WIRE LATH | Alejandro Corrales | APPROVED | | |
|
03/25/2021 | GAS LINE RGH IN-PL | Jan Trana | APPROVED | | 3/25/2021 12:43:24 PM
Need COP by final 2no dryer not on iso
3/25/2021 1:11:40 PM
Need COP by final 2no dryer not on iso
|
|
03/29/2021 | FRAMING | Joseph Robinson | PARTIAL APPROVAL | eTRAKiT Inspection Request | 3/26/2021 1:56:08 PM
3/26/2021 1:56 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
3/29/2021 5:36:12 PM
Plans show a knee wall in kitchen.
Submit a revision to show the wall has been removed.
Ok to insulate.
|
|
03/30/2021 | FRAMING | Wyatt T. Haygood | APPROVED | | |
|
04/01/2021 | INSULATION | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 3/31/2021 3:06:02 PM
3/31/2021 3:06 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
04/02/2021 | TILE IN PROGRESS | Alejandro Corrales | DISAPPROVED | | 4/2/2021 2:56:13 PM
No ladder
|
|
04/09/2021 | DRYWALL SCREW | Alejandro Corrales | APPROVED | | 4/8/2021 3:48:52 PM
ST
|
|
04/14/2021 | TILE IN PROGRESS | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 4/13/2021 8:12:20 PM
4/13/2021 8:12 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
04/21/2021 | ROOF FINAL | Alejandro Corrales | DISAPPROVED | eTRAKiT Inspection Request | 4/20/2021 6:18:40 PM
4/20/2021 6:18 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
4/21/2021 5:41:34 PM
1) Roof is missing 2 O'haggin vents. As per plan, Vera model roof requires 9 O'haggin vents. Only 7 are installed.
|
|
05/13/2021 | SIDEWALK SUB DENSITY | Perry Taborn | APPROVED | eTRAKiT Inspection Request | 5/12/2021 3:07:24 PM
5/12/2021 3:07 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
05/13/2021 | DW SUBGRADE DENSITY | Perry Taborn | APPROVED | eTRAKiT Inspection Request | 5/12/2021 3:07:03 PM
5/12/2021 3:07 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
05/14/2021 | SIDEWALK FORMS | Perry Taborn | APPROVED | | |
|
05/18/2021 | 30 DAY FOR TESTING | Joe Nieves | APPROVED | eTRAKiT Inspection Request | 5/17/2021 1:30:42 PM
5/17/2021 1:30 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/07/2021 | MECHANICAL FINAL | Scott Wiesel | APPROVED | eTRAKiT Inspection Request | 6/4/2021 3:37:29 PM
6/4/2021 3:37 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/16/2021 | PATIO SLAB/PAVERS | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 6/15/2021 9:48:33 AM
6/15/2021 9:48 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/16/2021 | DRIVEWAY STEEL/PAVER | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 6/15/2021 9:48:59 AM
6/15/2021 9:48 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/23/2021 | ELECTRIC FINAL | Joe Nieves | DISAPPROVED | eTRAKiT Inspection Request | 6/23/2021 1:36:33 AM
6/23/2021 1:36 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/23/2021 1:10:24 PM
Work Not Complete.
FBC 110.9.1
|
|
06/24/2021 | ELECTRIC FINAL | Joe Nieves | PARTIAL APPROVAL | eTRAKiT Inspection Request | 6/23/2021 8:34:24 PM
6/23/2021 8:34 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/24/2021 10:39:12 AM
Kitchen Island Not Complete.
|
|
06/24/2021 | IRRIGATION ROUGH | Jan Trana | DISAPPROVED | eTRAKiT Inspection Request | 6/23/2021 8:05:26 AM
6/23/2021 8:05 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/24/2021 12:19:56 PM
Not ready
6/24/2021 12:25:19 PM
Not ready
|
|
06/28/2021 | IRRIGATION ROUGH | Jeremy Hassenplug | APPROVED | eTRAKiT Inspection Request | 6/26/2021 2:39:29 PM
6/26/2021 2:39 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/28/2021 | SEWER FINAL | Jeremy Hassenplug | APPROVED | eTRAKiT Inspection Request | 6/25/2021 3:18:33 PM
6/25/2021 3:18 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
06/28/2021 | PLUMBING FINAL | Jeremy Hassenplug | DISAPPROVED | eTRAKiT Inspection Request | 6/25/2021 3:18:53 PM
6/25/2021 3:18 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/28/2021 2:00:07 PM
Not ready. Fixtures missing and water off to a few
|
|
06/28/2021 | FINAL GAS-PLUMBING | Jeremy Hassenplug | DISAPPROVED | eTRAKiT Inspection Request | 6/25/2021 6:00:40 PM
6/25/2021 6:00 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/28/2021 2:00:11 PM
Cop missing and gas not connected to the home
|
|
06/29/2021 | FINAL GAS-PLUMBING | Jeremy Hassenplug | DISAPPROVED | eTRAKiT Inspection Request | 6/28/2021 3:29:17 PM
6/28/2021 3:29 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
6/29/2021 2:38:33 PM
Cop not on site
|
|
07/02/2021 | PLUMBING FINAL | Jan Trana | DISAPPROVED | eTRAKiT Inspection Request | 7/1/2021 12:04:08 PM
7/1/2021 12:04 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/2/2021 12:33:15 PM
Missing sewer clean out
|
|
07/06/2021 | PLUMBING FINAL | Jan Trana | APPROVED | eTRAKiT Inspection Request | 7/2/2021 2:58:12 PM
7/2/2021 2:58 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/08/2021 | FINAL GAS-PLUMBING | Jan Trana | DISAPPROVED | eTRAKiT Inspection Request | 7/7/2021 3:07:39 PM
7/7/2021 3:07 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/8/2021 11:10:38 AM
Missing COP for second dryer. Second time
|
|
07/08/2021 | IRRIGATION FINAL | Jan Trana | PARTIAL APPROVAL | eTRAKiT Inspection Request | 7/7/2021 2:58:10 PM
7/7/2021 2:58 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/8/2021 11:10:41 AM
Pending cop as built
|
|
07/08/2021 | ENG DRAINAGE | Perry Taborn | APPROVED | eTRAKiT Inspection Request | 7/7/2021 2:57:23 PM
7/7/2021 2:57 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/08/2021 | ROOF FINAL | Alejandro Corrales | DISAPPROVED | eTRAKiT Inspection Request | 7/7/2021 3:00:26 PM
7/7/2021 3:00 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/8/2021 12:49:08 PM
No ladder
|
|
07/08/2021 | ELECTRIC FINAL | Joe Nieves | PARTIAL APPROVAL | eTRAKiT Inspection Request | 7/7/2021 3:07:12 PM
7/7/2021 3:07 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/8/2021 1:38:12 PM
Kitchen Island Wiring Not Complete.
FBC 110.9.1
|
|
07/08/2021 | LOW VOLTAGE FINAL | Joe Nieves | APPROVED | TV,PHONE,WIFI | 7/7/2021 3:46:09 PM
VB
|
|
07/08/2021 | LANDSCAPING | Patti Hoot | APPROVED | eTRAKiT Inspection Request | 7/7/2021 2:58:35 PM
7/7/2021 2:58 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/08/2021 | ZONING INSPECTION | Jean Panebianco | APPROVED | eTRAKiT Inspection Request | 7/7/2021 2:56:53 PM
7/7/2021 2:56 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/09/2021 | FINAL GAS-PLUMBING | Jeremy Hassenplug | DISAPPROVED | eTRAKiT Inspection Request | 7/8/2021 8:26:23 PM
7/8/2021 8:26 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/9/2021 12:03:22 PM
Cop not on site showing optional gas dryer. Pm will remove gas line to dryer as it is to be electric
7/9/2021 12:03:44 PM
Cop not on site showing optional gas dryer. Pm will remove gas line to dryer as it is to be electric
7/9/2021 12:04:27 PM
Cop not on site showing optional gas dryer. Pm will remove gas line to dryer as it is to be electric
7/9/2021 12:05:27 PM
Cop not on site showing optional gas dryer. Pm will remove gas line to dryer as it is to be electric
|
|
07/09/2021 | ROOF FINAL | Alejandro Corrales | DISAPPROVED | eTRAKiT Inspection Request | 7/8/2021 8:25:59 PM
7/8/2021 8:25 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/9/2021 2:53:24 PM
1) There are 5 broken tiles that need replacing and multiple crack and chipped tiles in the valley that need repairing.
|
|
07/13/2021 | ELECTRIC FINAL | Joe Nieves | APPROVED | eTRAKiT Inspection Request | 7/13/2021 4:12:40 AM
7/13/2021 4:12 AM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/15/2021 | FINAL SURVEY | Wyatt T. Haygood | APPROVED | | 7/15/2021 10:05:51 AM
Flood Zone X LOMR -F # 20-04-1589A
|
|
07/21/2021 | FINAL GAS-PLUMBING | Scott Wiesel | DISAPPROVED | eTRAKiT Inspection Request | 7/20/2021 8:17:01 PM
7/20/2021 8:17 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
7/21/2021 1:05:22 PM
House locked,no plans or permit
|
|
07/22/2021 | FINAL GAS-PLUMBING | Scott Wiesel | APPROVED | eTRAKiT Inspection Request | 7/21/2021 3:39:12 PM
7/21/2021 3:39 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/29/2021 | IRRIGATION FINAL | Jan Trana | APPROVED | eTRAKiT Inspection Request | 7/28/2021 6:04:28 PM
7/28/2021 6:04 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
07/29/2021 | BLOWER DOOR TEST | Dave Chin-Sang | APPROVED | | |
|
08/10/2021 | ROOF FINAL | Joseph Robinson | APPROVED | eTRAKiT Inspection Request | 8/9/2021 4:20:46 PM
8/9/2021 4:20 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
|
|
| ADMIN POOL COMPLETE | Victoria Barrios | | VOIDED (AD18 9/28/2021) | 9/20/2021 9:04:31 PM
9/20/2021 9:04 PM K. HOVNANIAN JV SERVICES COMPANY LLC
Contact Name: K. HOVNANIAN JV SERVICES COMPANY LLC
Site Address: 9360 PORTO WAY
Phone: 5613368847
e-Mail: jspalt@khov.com
9/28/2021 4:52:38 PM
Inspection voided by AD18. Most recent remarks follow: eTRAKiT Inspection Request
|
|
09/29/2021 | FINAL | Alejandro Corrales | APPROVED | | 9/28/2021 4:52:53 PM
vb
|
|
10/05/2021 | ADMIN CHECKLIST** | Victoria Barrios | APPROVED | | 10/5/2021 3:50:23 PM
FINAL TERMITE RECEIVED 10/5/2021
|
|