12/04/2020 | SOIL BEARING CERT | Wyatt T. Haygood | APPROVED | | |
|
12/04/2020 | SOIL TERMITE TREAT | Wyatt T. Haygood | APPROVED | | |
|
12/07/2020 | SLAB | Wyatt T. Haygood | DISAPPROVED | | 12/4/2020 11:11:26 AM
ST
12/7/2020 1:41:56 PM
Top and bottom steel in footings required to be # 6 steel.
Transfer steel and transverse steel required to be 12 inch on center maximum.
All steel requires three inch minimum concrete coverage from dirt and forms.
C3 column anchor bolts require 12 inch minimum embedment.
Special inspector required to inspect slab.
|
|
12/10/2020 | SLAB | Will Jorge | CANCELLED BY PERMITE | | |
|
12/14/2020 | SLAB | Wyatt T. Haygood | APPROVED | | |
|
05/18/2021 | SPOT SURVEY | Wyatt T. Haygood | DISAPPROVED | | 5/18/2021 10:09:16 AM
Finish Floor Elevation is below Base Flood Elevation.
Minimum Elevation of 16.00 is required or wet floodproofing of Building is required.
(FBC 1612.1, 1612.4, 1612.4.1)
|
|
06/29/2021 | SPOT SURVEY | Wyatt T. Haygood | APPROVED | | 6/29/2021 9:30:42 AM
Flood Vents added
|
|
07/09/2021 | ENG MISC | Perry Taborn | APPROVED | check grading around slab | 7/8/2021 1:16:54 PM
JS
|
|
07/14/2021 | ROOF SHEATHING | Tony Willson | APPROVED | | 7/13/2021 7:53:28 AM
wth
|
|
07/14/2021 | WALL SHEATHING | Tony Willson | APPROVED | BUILDING CLADDING | 7/13/2021 7:52:25 AM
wth
|
|
07/14/2021 | FRAMING | Tony Willson | APPROVED | eTRAKiT Inspection Request | 7/12/2021 12:24:39 PM
7/12/2021 12:24 PM SHIFF CONSTRUCTION & DEVELOPMENT INC
Please call Kurt with any questions - 954-812-9945
Contact Name: SHIFF CONSTRUCTION & DEVELOPMENT INC
Site Address: 6500 PARKSIDE DR
Phone: 9545242575
e-Mail: RIA@SHIFF.COM
|
|
07/20/2021 | PE CERTIFICATION | Wyatt T. Haygood | APPROVED | STEEL BLDG CONNECTIONS | |
|
07/22/2021 | ZONING INSPECTION | Jean Panebianco | APPROVED | eTRAKiT Inspection Request | 7/21/2021 3:08:01 PM
7/21/2021 3:08 PM SHIFF CONSTRUCTION & DEVELOPMENT INC
Kurt Bennett 954-812-9945
Contact Name: SHIFF CONSTRUCTION & DEVELOPMENT INC
Site Address: 6500 PARKSIDE DR
Phone: 9545242575
e-Mail: RIA@SHIFF.COM
|
|
07/27/2021 | FINAL SURVEY | Wyatt T. Haygood | DISAPPROVED | | 7/27/2021 3:41:25 PM
Flood Vents required to be installed and documented on Elevation Certificate
|
|
08/11/2021 | FINAL SURVEY | Bill Tracy | APPROVED | | 8/11/2021 1:30:19 PM
ENGINEERED FLOOD OPENINGS
|
|
08/18/2021 | FINAL | Will Jorge | APPROVED | | 8/17/2021 8:26:13 AM
JS
|
|
08/18/2021 | ADMIN CHECKLIST** | Juan Soto | APPROVED | | |
|