05/03/2024
9:18 PM
 
Permit No. BLDG2101-0013 Permit Type   OUT BUILDING Site Address   7957 BLUE SAGE WAY
PARKLAND, FL 33076
Applied   01/05/2021 Applicant  
Approved   04/16/2021 Owner   LAVAN,KENNETH L & ADRIANA
Issued   04/26/2021 Contractor   TORCON USA INC
Parent Permit No.   Description   ACCESORY STRUCTURE
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 04/14/2021PRODUCT APPROVALSBill TracyAPPROVED

 04/26/2021NOCDebbie GrosseAPPROVED

 04/29/2021NPDES InitialPerry TabornAPPROVED4/28/2021 7:59:51 AM City of Parkland Request for Inspection Form Permit Number 21010013 First Name Adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested NPDES Initial Request Date 4/29/2021

 05/18/2021SEWER CONNECTIONJeremy HassenplugAPPROVED5/17/2021 4:15:21 PM ST 5/17/2021 4:15:42 PM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21010013 First Name Adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested Plumbing: 2: Sewer connection Request Date 5/18/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to Etrakit please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at (954) 753-5447.

 05/19/2021WATER SERVICEJan TranaAPPROVED

 05/19/2021GROUND ROUGHJan TranaDISAPPROVED5/19/2021 2:42:11 PM No water in sanitary

 05/21/2021GROUND ROUGHJan TranaDISAPPROVED5/19/2021 3:15:42 PM vb 5/21/2021 12:05:39 PM No water in sanitary

 05/21/2021CONDENSATE LINEJan TranaDISAPPROVED5/20/2021 1:29:39 PM vb 5/21/2021 12:05:42 PM Not ready

 05/21/2021SERVICE GROUNDDavid HayesDISAPPROVEDNOT READY.5/20/2021 1:30:08 PM vb 5/21/2021 1:51:06 PM Nothing installed for grounding yet.

 05/21/2021UNDERGROUNDDavid HayesPARTIAL APPROVALFEED TO PANEL AND FLOOR BOX

 05/25/2021SERVICE GROUNDDean DiBisceglieAPPROVED5/24/2021 4:41:51 PM vb

 05/25/2021GROUND ROUGHJan TranaAPPROVED5/24/2021 4:41:41 PM vb

 05/25/2021CONDENSATE LINEJan TranaDISAPPROVED5/24/2021 4:41:12 PM vb 5/25/2021 11:28:02 AM Not ready

 05/26/2021CONDENSATE LINEJan TranaAPPROVED

 06/02/2021SOIL BEARING CERTBill TracyAPPROVED6/2/2021 5:13:07 PM STATEMENT OF SOIL BEARING FROM PANGEO CONSULTANTS, WITH DENSITIES, ATTESTING TO A BEARING CAPACITY OF 3000 PSF

 06/02/2021SOIL TERMITE TREATBill TracyAPPROVED6/2/2021 5:14:15 PM .1% IMIDACLOPRID

 06/03/2021TRUSS PLANS ON FILEBill TracyAPPROVEDSUBMITTED ONLY

 06/04/2021SLABWill JorgeAPPROVED6/3/2021 1:33:53 PM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21010013 First Name adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested Structural: Slab inspection Request Date 6/4/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to Etrakit please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at (954) 753-5447.

 06/15/2021SPOT SURVEYWyatt T. HaygoodAPPROVED

 06/03/2021SPOT SURVEYBill TracyDISAPPROVED6/3/2021 12:02:14 PM missing slab inspection

 06/25/2021TIE BEAM/BONDWill JorgeAPPROVED6/24/2021 1:34:05 PM ST

 07/02/2021UNIT MASONRY CERTBill TracyAPPROVED7/2/2021 12:01:02 PM UNIT MASONRY CERTIFICATION SUBMITTED BY ALI YEMENICILER, PE

 07/20/2021ROOF SHEATHINGWill JorgeAPPROVED

 07/20/2021WALL SHEATHINGWill JorgeAPPROVED

 07/20/2021TRUSSWill JorgeAPPROVED

 07/22/2021TIN CAPAlejandro CorralesAPPROVED7/21/2021 11:49:20 AM wth

 07/22/2021HOT MOP IN PROGRESSAlejandro CorralesDISAPPROVED7/21/2021 12:56:49 PM VB 7/22/2021 4:54:33 PM 1) peel and stick cap sheets must be completed 100% before scheduling inspection. Only actual hot mop applications shall be inspected in progress. Please finish installing peel and stick caps sheet and reschedule hot mop inspection

 07/28/2021HOT MOP IN PROGRESSWill JorgeAPPROVED

 08/09/2021WIND/DOOR BUCKTony WillsonAPPROVED8/6/2021 2:04:34 PM ST

 08/31/2021LOW VOLTAGE ROUGHDean DiBisceglieAPPROVED

 08/31/2021ELECTRIC ROUGHDean DiBisceglieAPPROVED

 08/31/2021EXHAUST ROUGHDave Chin-SangDISAPPROVED8/31/2021 12:09:03 PM Roof termination not connected

 08/31/2021ROUGH DUCTDave Chin-SangDISAPPROVED8/31/2021 12:09:04 PM Main supply trunk line touching roof deck. Unable to spray foam.

 08/31/2021WIRE LATHJoseph RobinsonAPPROVED

 08/31/2021WIND/DOOR ATTACHMENTJoseph RobinsonPARTIAL APPROVALEXCEPT FRONT DOOR8/31/2021 1:57:37 PM Pending front door.

 09/07/2021ROUGH DUCTDave Chin-SangAPPROVED

 09/07/2021EXHAUST ROUGHDave Chin-SangAPPROVED

 09/07/2021SHOWER PANJeremy HassenplugAPPROVED

 09/07/2021TOP OUTJeremy HassenplugAPPROVED

 09/08/2021FRAMINGJoseph RobinsonDISAPPROVED9/8/2021 3:28:42 PM Draft stop incomplete. Multiple penetrations in top track. Furring incomplete.

 09/10/2021FRAMINGAlejandro CorralesDISAPPROVED9/10/2021 1:57:24 PM 1) Furring incomplete. Draft stop at top of wall no done. There is a gap above most of the furring strips. There should be a piece of furring or foam blocking airflow within the wall every 10 feet. Air and smoke shall not move through the wall more than 10 feet in any direction. 2) Exterior wall penetrations shall be stuccoed, not foamed. Stucco any penetrations and recessed electrical boxes in block wall. PROTECT COPPER PIPES FROM STUCCO AND FROM BARE BLOCK.. SHOULD BE SLEEVED. 3) some top track penetrations needing foam, marked on floor with sharpie.

 09/13/2021FRAMINGWyatt T. HaygoodAPPROVED

 09/15/2021INSULATIONJoseph RobinsonAPPROVEDSPRAY FOAM9/14/2021 7:14:49 AM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21010013 First Name Adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested Structural: Insulation Request Date 9/14/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to eTRAKiT please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at 954.753.5447.

 09/16/2021TILE IN PROGRESSWill JorgeCANCELLED BY PERMITE9/16/2021 7:48:30 AM holiday

 09/20/2021TILE IN PROGRESSWyatt T. HaygoodAPPROVED9/16/2021 8:05:09 AM City of Parkland Request for Inspection Form Permit Number 21010013 First Name Adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested Structural: Roof tile in progress Request Date 9/20/2021

 09/21/2021DRYWALL SCREWJoseph RobinsonAPPROVED9/20/2021 4:02:51 PM VB

 09/22/2021ROOF TILE UPLIFT TSTBill TracyAPPROVED9/22/2021 1:56:34 PM UPLIFT REPORT SUBMITTED FROM ACB2 ENGINEERING - PASS

 10/01/2021ROOF FINALAlejandro CorralesAPPROVED9/30/2021 7:25:37 AM City of Parkland Request for Inspection Form Permit Number 21010013 First Name Adriano Last Name Cartelli Company Torcon USA, Inc Phone Number 5619894991 Email Address torconusa@outlook.com Type of Inspection(s) Requested Structural: Roof final Request Date 10/1/2021

 10/12/2021SHOWER PANJan TranaAPPROVEDWALL WATERPROOFING

 12/22/2021ZONING INSPECTIONJean PanebiancoAPPROVED

 12/22/2021LOW VOLTAGE FINALDean DiBisceglieAPPROVED

 12/22/2021ELECTRIC FINALDean DiBisceglieAPPROVED

 12/22/2021ENG MISCPerry TabornAPPROVEDCheck grading around building

 12/22/2021PLUMBING FINALJeremy HassenplugAPPROVED

 12/22/2021MECHANICAL FINALDave Chin-SangDISAPPROVED12/22/2021 1:09:53 PM A/C equipment doesn't mat approved plan. Plan shows 2tons 17 seer. 2..5 tons 14seer installed. Low voltage wire to c/u needs protection. C.O.P Required for return grill location

 12/22/2021FINAL SURVEYBill TracyAPPROVED

 01/11/2022BLOWER DOOR TESTDave Chin-SangAPPROVED4/13/2021 5:30:26 PM ACH Max 5.0

 02/10/2022MECHANICAL FINALDave Chin-SangDISAPPROVED2/9/2022 4:08:32 PM MT 2/10/2022 9:39:38 AM Condensate termination needs to be minimum 12" away from wall. Corrections not done supply plenum not sealed. Low voltage wires needs protection @C/U

 02/11/2022MECHANICAL FINALDave Chin-SangAPPROVEDPER Photos

 03/15/2022UNDERGROUNDJoe NievesAPPROVEDFEED FROM SERVICE3/15/2022 2:28:21 PM Partial Underground Approved On 5-2-2021 All Underground Covered / 3-15-2022 3/15/2022 2:29:09 PM Partial Underground Approved On 5-2-2021 All Underground Covered / 3-15-2022

 03/15/2022WIND/DOOR ATTACHMENTWill JorgeAPPROVED

 03/16/2022FINALWill JorgeAPPROVED

 04/22/2022ADMIN CHECKLIST**Victoria BarriosAPPROVED