03/02/2022 | NOC | Debbie Grosse | APPROVED | | |
|
12/08/2021 | TRUSS PLANS ON FILE | Bill Tracy | APPROVED | | |
|
04/07/2022 | SOIL BEARING CERT | Wyatt T. Haygood | DISAPPROVED | eTRAKiT Inspection Request | 4/6/2022 3:02:30 PM
4/6/2022 3:02 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
4/7/2022 7:30:18 AM
Soil Bearing Certificate required to be submitted to City of Parkland Building Department for review and approval.
|
|
04/07/2022 | SOIL BEARING CERT | Wyatt T. Haygood | APPROVED | | |
|
04/07/2022 | FOOTER BOND | Pedro Vieira | APPROVED | | |
|
04/08/2022 | SLAB | Will Jorge | DISAPPROVED | eTRAKiT Inspection Request | 4/7/2022 12:22:33 PM
4/7/2022 12:22 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
4/8/2022 3:12:50 PM
iso's have back wash burning steel, water in stemwall 3"min. concrete coverage on steel
|
|
04/12/2022 | FOOTER/FOUNDATION | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 4/11/2022 10:54:32 AM
4/11/2022 10:54 AM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
05/03/2022 | SLAB | Tony Willson | APPROVED | | 5/2/2022 10:46:28 AM
ST
|
|
05/03/2022 | TIE BEAM/BOND | Tony Willson | APPROVED | | 5/2/2022 3:22:30 PM
Tie Beam inspection at contractors own risk, no spot survey submitted for location.
|
|
05/11/2022 | UNIT MASONRY CERT | Bill Tracy | APPROVED | | 5/11/2022 8:57:17 AM
UNIT MASONRY CERTIFICATION RECEIVED FROM BRENNAN ENGINEERING
|
|
05/11/2022 | GAS LINE RGH OUT-PL | Jeremy Hassenplug | DISAPPROVED | eTRAKiT Inspection Request | 5/10/2022 8:55:36 AM
5/10/2022 8:55 AM PROMARC INC.
Joe ditto gas service
954-465-7157
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
5/11/2022 11:21:15 AM
APPROVED PLAN NOT ON SITE
|
|
05/18/2022 | UNDERGROUND | Dean DiBisceglie | APPROVED | eTRAKiT Inspection Request | 5/17/2022 12:26:48 PM
5/17/2022 12:26 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
05/18/2022 | GAS LINE RGH OUT-PL | Jeremy Hassenplug | APPROVED | eTRAKiT Inspection Request | 5/17/2022 12:27:21 PM
5/17/2022 12:27 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
05/24/2022 | TRUSS | Alejandro Corrales | DISAPPROVED | | 5/23/2022 10:54:17 AM
ST
5/24/2022 4:47:57 PM
7 truss tails are more than 1/2'' separated from fascia. When this happens you must install blocking from the truss to the fascia to complete the connection. 7 truss tails around the structure need blocking. Some of the jack trusses look like they might be missing slant nails (toenails). Other than that, truss looks ok.
|
|
05/24/2022 | ROOF SHEATHING | Alejandro Corrales | APPROVED | | 5/23/2022 10:50:49 AM
ST
|
|
05/27/2022 | TRUSS | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 5/26/2022 12:00:55 PM
5/26/2022 12:00 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
05/31/2022 | SPOT SURVEY | Wyatt T. Haygood | APPROVED | | |
|
05/31/2022 | TIN CAP | Joseph Robinson | APPROVED | | |
|
06/02/2022 | ELECTRIC ROUGH | Joe Nieves | DISAPPROVED | eTRAKiT Inspection Request | 6/1/2022 3:20:28 PM
6/1/2022 3:20 PM PROMARC INC.
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
6/2/2022 11:17:42 AM
A Disconnecting Means For A Separate Structure Has Not Been Installed In Compliance With The NEC Article 225.32
Work Not Complete/ FBC 110.9.1
|
|
06/06/2022 | ELECTRIC ROUGH | Joe Nieves | PARTIAL APPROVAL | eTRAKiT Inspection Request | 6/3/2022 3:32:07 PM
6/3/2022 3:32 PM PROMARC INC.
John manni will call Joe direct for the onsite meeting time frame
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
6/6/2022 12:55:59 PM
Work Not Complete/ Partial Approval
6/6/2022 12:57:03 PM
Work Not Complete/ Partial Approval
|
|
06/09/2022 | WIRE LATH | Joseph Robinson | APPROVED | | 6/8/2022 10:42:48 AM
JS
|
|
06/10/2022 | HOT MOP IN PROGRESS | Will Jorge | APPROVED | | 6/8/2022 10:42:35 AM
JS
|
|
08/02/2022 | ELECTRIC ROUGH | David Hayes | PARTIAL APPROVAL | eTRAKiT Inspection Request. SEE NOTES. | 8/1/2022 12:43:52 PM
8/1/2022 12:43 PM PROMARC INC.
bbq all rough ready fro inspection
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
8/2/2022 1:01:56 PM
1. Partial only for Summer Kitchen block wall. OK to Pour.
2. Still require a means of disconnect and the required electrode for this detached structure. See previous red tag. NEC. 225.32 and NEC 250.32
3. A change of plan is required prior to final. BCA FBC 107.3.5(B)
|
|
08/08/2022 | TILE IN PROGRESS | Joseph Robinson | APPROVED | | 8/5/2022 10:44:32 AM
an
|
|
08/25/2022 | ROOF TILE UPLIFT TST | Wyatt T. Haygood | APPROVED | | |
|
08/31/2022 | ROOF FINAL | Joseph Robinson | APPROVED | | 8/30/2022 11:24:14 AM
MT
|
|
10/20/2022 | LOW VOLTAGE ROUGH | Pedro Vieira | DISAPPROVED - FEE | ADD SPKS | 10/19/2022 12:06:11 PM
ST
10/20/2022 10:01:34 AM
2. Still require a means of disconnect and the required electrode for this detached structure. See previous red tag. NEC. 225.32 and NEC 250.32
3. A change of plan is required prior to final. BCA FBC 107.3.5(B)
______________________________________________________________
Adjustments were not done from previous inspection.
|
|
10/20/2022 | ELECTRIC ROUGH | Pedro Vieira | DISAPPROVED - FEE | eTRAKiT Inspection Request | 10/18/2022 1:19:53 PM
10/18/2022 1:19 PM PROMARC INC.
job complete as builts on site
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
10/20/2022 10:03:56 AM
2. Still require a means of disconnect and the required electrode for this detached structure. See previous red tag. NEC. 225.32 and NEC 250.32
3. A change of plan is required prior to final. BCA FBC 107.3.5(B)
______________________________________________________________
Work was not completed according to previous inspection.
|
|
10/20/2022 | FINAL GAS-PLUMBING | Jeremy Hassenplug | APPROVED | | 10/19/2022 12:07:02 PM
ST
|
|
10/21/2022 | LOW VOLTAGE ROUGH | David Hayes | APPROVED | REQUESTING D.HAYES | 10/20/2022 2:59:56 PM
JS
|
|
10/21/2022 | LOW VOLTAGE FINAL | David Hayes | APPROVED | ADD SPKS | |
|
10/21/2022 | ELECTRIC FINAL | David Hayes | APPROVED | | |
|
10/21/2022 | ELECTRIC ROUGH | Pedro Vieira | PARTIAL APPROVAL | STILL WAITING FOR DISCONNECT | 10/20/2022 2:59:43 PM
JS
|
|
10/21/2022 | ELECTRIC ROUGH | David Hayes | APPROVED | | |
|
10/28/2022 | ZONING INSPECTION | Jean Panebianco | APPROVED | eTRAKiT Inspection Request | 10/26/2022 9:46:50 AM
10/26/2022 9:46 AM PROMARC INC.
AM
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
11/03/2022 | FINAL SURVEY | Wyatt T. Haygood | DISAPPROVED | | 11/3/2022 8:21:41 AM
Final Survey required to be Signed and Sealed by Surveyor.
Note: Sheet 1 of 2 was not submitted
(F.S. 472.025)
Elevation Certificate required to be submitted
|
|
11/30/2022 | FINAL SURVEY | Wyatt T. Haygood | DISAPPROVED | eTRAKiT Inspection Request | 11/29/2022 11:20:18 AM
11/29/2022 11:20 AM PROMARC INC.
AM
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
11/30/2022 7:15:01 AM
Final Survey with Elevation Certificate required to be submitted to city of parkland building department for review and approval.
|
|
12/19/2022 | FINAL SURVEY | Bill Tracy | APPROVED | | 12/19/2022 3:13:47 PM
SHADED X ZONE
|
|
12/23/2022 | FINAL | Alejandro Corrales | APPROVED | eTRAKiT Inspection Request | 12/22/2022 12:07:18 PM
12/22/2022 12:07 PM PROMARC INC.
AM
Contact Name: PROMARC INC.
Site Address: 10485 N BARNSLEY DR
Phone: 9545202397
e-Mail: SALES@PROMARCINC.COM
|
|
12/30/2022 | ADMIN CHECKLIST** | Victoria Barrios | APPROVED | | |
|