04/29/2024
3:45 AM
 
Permit No. BLDG2205-0150 Permit Type   ST MISC Site Address   8681 LAKESIDE BND
PARKLAND, FL 33076
Applied   05/17/2022 Applicant  
Approved   12/01/2022 Owner   TRENCHFIELD,IAN
Issued   02/28/2023 Contractor   METZKER LLC
Parent Permit No.   Description   OUTDOOR KITCHEN
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/10/2023GROUND ROUGHJeremy HassenplugDISAPPROVED3/9/2023 2:50:11 PM ST 3/10/2023 12:04:17 PM Work covered

 03/14/2023GROUND ROUGHJan TranaDISAPPROVED3/14/2023 2:31:07 PM Work covered second time

 03/21/2023GROUND ROUGHJan TranaDISAPPROVED3/20/2023 11:58:37 AM vb 3/21/2023 12:21:18 PM Sewer not deep enough, P2604.3 Sewer fittings not per code P3002..3.1 Sewer needs clean out P3005.2.4 Sewer not tested P2503.5.1 (1) Water covered and tested P2503.7

 03/27/2023GROUND ROUGHJeremy HassenplugDISAPPROVED - FEE3/24/2023 12:44:35 PM MT 3/27/2023 11:27:32 AM PERMIT CARD NOT POSTED APPROVED PLAN NOT ON SITE Comment not addressed Sewer not deep enough, P2604.3 Water covered and Sewer not deep enough, P2604.3 Water covered and not tested P2503.7 Waterline still covered, unable to see connection point or material ran underground Second PVC drain stub up covered and doesn't appear to be connected to sewer ran to front of home

 03/30/2023GROUND ROUGHJan TranaPARTIAL APPROVAL3/29/2023 3:03:55 PM MT 3/30/2023 2:31:34 PM Just missing connection to existing sewer. Call when ready. Everything else is fine to backfill.

 04/14/2023UNDERGROUNDPedro VieiraAPPROVEDelectric pipe for outdoor kitchen

 04/14/2023FRAMINGAlejandro CorralesDISAPPROVED4/13/2023 4:09:17 PM JS - OKAYED BY WIL JORGE 4/14/2023 4:04:22 PM Submit change of plan for summer kitchen, changing the masonry framing detail to a metal framing detail. Plan shows the summer kitchen formed using 8 inch masonry blocks. It is currently framed out of 16 gauge metal studs.

 04/17/2023GROUND ROUGHJeremy HassenplugCANCELLED BY PERMITE4/13/2023 4:09:51 PM JS 4/17/2023 7:47:42 AM DANIEL

 04/17/2023TOP OUTJeremy HassenplugCANCELLED BY PERMITE4/13/2023 4:10:08 PM JS 4/17/2023 7:48:35 AM DANIEL

 04/18/2023TOP OUTJeremy HassenplugDISAPPROVED4/17/2023 7:49:03 AM ST 4/18/2023 10:12:32 AM Not ready

 04/18/2023GROUND ROUGHJeremy HassenplugDISAPPROVED4/17/2023 7:48:19 AM ST 4/18/2023 10:12:34 AM Work covered, connection to sewer not exposed for inspection

 04/19/2023DRYWALL SCREWJoseph RobinsonAPPROVED

 04/19/2023FRAMINGJoseph RobinsonAPPROVED

 04/20/2023TOP OUTJeremy HassenplugAPPROVED

 04/21/2023GROUND ROUGHJan TranaDISAPPROVED4/21/2023 12:03:09 PM FRC P3005.4 Pipe size can not reduced in the direction of flow. Sewer connection not visible

 05/01/2023ELECTRIC ROUGHPedro VieiraDISAPPROVED4/13/2023 4:09:30 PM JS 4/28/2023 3:44:54 PM MT 5/1/2023 11:00:46 AM Work not complete Missing outlets Liquidtight shall not be exposed to any physical damage Unused openings shall be closed with KO seal

 05/01/2023GAS LINE RGH OUT-PLJeremy HassenplugAPPROVED4/28/2023 3:45:04 PM MT

 05/03/2023ELECTRIC ROUGHPedro VieiraAPPROVED

 06/09/2023ELECTRIC FINALRinor KrasniqiDISAPPROVED6/8/2023 8:58:38 AM vb 6/9/2023 10:41:16 AM Fastened in appliances don't have readily accessible disconnects Unable to test appliance receptacles, please plug appliance in so I can confirm receptacles work Labeling not suitable for corrosive environment next to pool equipment, please print and stick new labeling

 06/09/2023GROUND ROUGHJeremy HassenplugDISAPPROVED - FEE6/8/2023 8:58:52 AM vb 6/9/2023 10:49:23 AM Work covered

 07/13/2023FINAL GAS-PLUMBINGJeremy HassenplugAPPROVED7/12/2023 3:54:55 PM FM

 02/28/2023NOCDebbie GrosseAPPROVED

 09/05/2023GROUND ROUGHJan TranaDISAPPROVED9/1/2023 10:25:36 AM MT 9/5/2023 10:56:46 AM PERMIT CARD NOT POSTED APPROVED PLAN NOT ON SITE WORK COVERED

 09/05/2023ELECTRIC FINALJoe NievesDISAPPROVED9/1/2023 10:25:05 AM MT 9/5/2023 1:39:51 PM 1) THE [GFCI] RECEPTACLE BELOW THE SINK, IS NOT [READILY ACCESSIBLE] PROTECTION MUST BE PROVIDED ELSEWHERE. 2) AN APPROVED PLAN MATCHING THE FIELD INSTALLATION IS REQUIRED FOR [FINAL ELECTRIC] INSPECTION, THE APPROVED PLAN MUST REFLECT THE [SOURCE POWER]/ LOAD CENTER. NEC 210.8 NEC 100 DEFINITIONS [ACCESSIBLE] FBC 107.3.1

 10/03/2023ELECTRIC FINALRinor KrasniqiAPPROVED10/2/2023 5:00:40 PM ST

 10/05/2023GROUND ROUGHJan TranaDISAPPROVED10/3/2023 4:49:26 PM FM

 10/16/2023GROUND ROUGHJan TranaDISAPPROVED - FEE10/12/2023 10:58:21 AM ST 10/13/2023 8:23:28 AM FM 10/16/2023 10:58:53 AM NO ACCESS WORK COVERED

 10/20/2023GROUND ROUGHJan TranaAPPROVED

 11/29/2023PLUMBING FINALJan TranaAPPROVED11/28/2023 4:02:57 PM VB

 11/30/2023FINAL**Anthony CrisantiAPPROVEDCHECK FEES DUE11/29/2023 11:34:45 AM JS 11/30/2023 7:41:43 AM 10-12