07/14/2020 | NOC | Debbie Grosse | APPROVED | | |
|
07/15/2020 | NPDES INITIAL | Perry Taborn | APPROVED | | 7/14/2020 11:12:46 AM
la
|
|
07/23/2020 | ELEC POOL STEEL BOND | Joe Nieves | APPROVED | | 7/22/2020 3:05:34 PM
JS
|
|
07/23/2020 | MAIN DRAIN | Jan Trana | APPROVED | | 7/22/2020 3:05:45 PM
JS
|
|
07/23/2020 | POOL STEEL | Alejandro Corrales | APPROVED | | 7/22/2020 3:05:56 PM
JS
|
|
08/13/2020 | PERIMETER PIPING | Jan Trana | APPROVED | | 8/12/2020 4:03:11 PM
ST
|
|
08/13/2020 | UNDERGROUND | David Hayes | APPROVED | | 8/12/2020 4:03:50 PM
ST
|
|
08/28/2020 | DECK BOND | Joe Nieves | DISAPPROVED | | 8/28/2020 2:20:47 PM
Work Not Complete.
FBC 110.9.
|
|
08/28/2020 | ENG ROUGH GRADE | Perry Taborn | APPROVED | | 8/27/2020 4:25:48 PM
JS
8/28/2020 12:23:54 PM
Restore swales for positive drainage, keep sidewalk and valley gutter in home front clear of debris
|
|
09/11/2020 | TIE BEAM/BOND | Will Jorge | APPROVED | | 9/10/2020 3:55:12 PM
vb
9/11/2020 2:10:56 PM
retaining wall
|
|
08/28/2020 | FOOTER/FOUNDATION | Will Jorge | APPROVED | retaining wall | 8/28/2020 2:34:11 PM
pending steel bond
|
|
09/09/2020 | ELEC POOL STEEL BOND | Dean DiBisceglie | APPROVED | retaining wall | |
|
09/08/2020 | TIE BEAM/BOND | Will Jorge | DISAPPROVED | retaining wall | 9/4/2020 3:57:00 PM
ok to pour take photos
9/8/2020 1:26:40 PM
work not per plan., area omitted at corner of pool requires retaining wall as per plan, some areas filling cells with fill and rock, not topped off with concrete ,inspection stopped.
|
|
09/11/2020 | DECK BOND | CAP Gov EL | APPROVED | | 9/10/2020 3:53:02 PM
vb
|
|
10/05/2020 | DECK STEEL/PAVERS | Wyatt T. Haygood | APPROVED | | 8/27/2020 4:25:36 PM
JS
|
|
10/08/2020 | FENCE BOND | Dean DiBisceglie | APPROVED | not required | 10/7/2020 4:04:09 PM
vb
|
|
10/08/2020 | FENCE | Joseph Robinson | DISAPPROVED | EXISTING 1912-0096 | 10/7/2020 4:03:57 PM
vb
10/8/2020 3:25:29 PM
Install southwest side of fence then recall inspection.
Work incomplete.
|
|
10/30/2020 | SAFETY ACT 515 | Alejandro Corrales | DISAPPROVED - FEE | | 10/29/2020 11:55:08 AM
NELSON
10/30/2020 5:51:36 PM
1) Pool filled prior to receiving Safety Act and Fence inspection approval!!!!
2) Right fence gate needs adjustment in order to close correctly
3) Right side of fence has 2 post with inadequate concrete coverage. Posts pull out by hand.
4) Back gate needs to be regraded in order to open and close.
5) Exit alarms were installed too low. Alarms must be a minimum of 54" from the floor.
6) Left gate is missing post cap.
|
|
10/30/2020 | FENCE | Alejandro Corrales | DISAPPROVED | | 10/29/2020 11:54:34 AM
NELSON
10/30/2020 5:52:16 PM
1) Pool filled prior to receiving Safety Act and Fence inspection approval!!!!
2) Right fence gate needs adjustment in order to close correctly
3) Right side of fence has 2 post with inadequate concrete coverage. Posts pull out by hand.
4) Back gate needs to be regraded in order to open and close.
5) Exit alarms were installed too low. Alarms must be a minimum of 54" from the floor.
6) Left gate is missing post cap.
|
|
11/16/2020 | FENCE | Joseph Robinson | DISAPPROVED | | 11/13/2020 11:21:28 AM
vb
11/16/2020 3:19:08 PM
Left gate missing post cap.
Unable to check back gate because it was locked.
|
|
11/16/2020 | SAFETY ACT 515 | Joseph Robinson | DISAPPROVED - FEE | | 11/13/2020 11:21:40 AM
vb
11/16/2020 3:19:13 PM
Left gate missing post cap.
Unable to check back gate because it was locked.
Exit alarms on windows installed too low. Must be a minimum of 54" from interior floor.
Pool filled with water prior to passing "Saftey Act" inspection!
|
|
11/20/2020 | ELECTRIC FINAL | Joe Nieves | DISAPPROVED | | 11/19/2020 2:39:49 PM
wth
11/20/2020 1:19:50 PM
The 3/4" PVC Conduit @ The Service Requires Support In Compliance With The NEC Code Article 352.30
Work Not Complete. FBC 110.9.1
|
|
11/20/2020 | SAFETY ACT 515 | Wyatt T. Haygood | CANCELLED BY PERMITE | | 11/19/2020 2:39:11 PM
wth
|
|
11/20/2020 | FENCE | Wyatt T. Haygood | CANCELLED BY PERMITE | | 11/19/2020 2:40:44 PM
wth
|
|
11/23/2020 | FENCE | Wyatt T. Haygood | DISAPPROVED | | 11/23/2020 3:29:23 PM
rear gate and north side gates are not closing.
|
|
12/03/2020 | FENCE | Wyatt T. Haygood | APPROVED | | 12/3/2020 8:08:01 AM
wth
|
|
12/03/2020 | SAFETY ACT 515 | Wyatt T. Haygood | APPROVED | | 12/3/2020 8:08:34 AM
wth
|
|
12/07/2020 | LANDSCAPING | Patti Hoot | DISAPPROVED | | 12/4/2020 3:37:49 PM
VB
12/7/2020 9:12:42 AM
Pool equipment needs to be screened, in this instance a faux green panel can be placed on the fence, and all grading, sod and landscape needs to be repaired
|
|
12/07/2020 | GAS LINE RGH OUT-PL | Dave Chin-Sang | APPROVED | | |
|
12/07/2020 | ENG MISC | Perry Taborn | APPROVED | | 12/4/2020 3:37:15 PM
VB
|
|
01/06/2021 | LANDSCAPING | Patti Hoot | DISAPPROVED | | 1/4/2021 9:24:28 AM
ST
1/6/2021 9:39:13 AM
Due to limited planting space a faux hedge screen will need to be installed on the fence to block visibility of equipment by neighbors
|
|
01/07/2021 | FINAL GAS-PLUMBING | Jan Trana | APPROVED | | 1/6/2021 10:44:36 AM
ST
|
|
03/29/2021 | ELECTRIC FINAL | David Hayes | APPROVED | | 3/26/2021 12:43:06 PM
th
|
|
05/17/2021 | LANDSCAPING | Patti Hoot | APPROVED | | 5/13/2021 1:20:51 PM
vb
5/17/2021 1:01:41 PM
Faux landscaping installed on the fence to block view of equipment from neighbors
5/19/2021 8:34:42 AM
Faux landscaping installed on the fence to block view of equipment from neighbors
|
|
05/18/2021 | PLUMBING POOL FINAL | Jeremy Hassenplug | DISAPPROVED | | 5/17/2021 2:33:03 PM
ST
5/18/2021 2:08:53 PM
Plans and permit not on site.
Pool piping not labeled
|
|
05/21/2021 | PLUMBING POOL FINAL | Jan Trana | APPROVED | | 5/20/2021 3:02:30 PM
JS
|
|
05/25/2021 | FINAL SURVEY | Wyatt T. Haygood | APPROVED | | |
|
05/26/2021 | FINAL** | Joseph Robinson | APPROVED | | 5/25/2021 11:43:37 AM
ST
|
|