10/21/2020 | NOC | Debbie Grosse | APPROVED | | |
|
03/08/2021 | NPDES INITIAL | Perry Taborn | DISAPPROVED | | 3/8/2021 11:47:40 AM
No silt fence installed
3/8/2021 11:49:11 AM
No silt fence installed
|
|
03/09/2021 | NPDES INITIAL | Perry Taborn | APPROVED | | 3/8/2021 3:17:24 PM
ST
3/9/2021 8:58:57 AM
Maintain fence
|
|
03/11/2021 | MAIN DRAIN | Jan Trana | DISAPPROVED | | 3/9/2021 3:07:35 PM
JS
3/11/2021 11:22:13 AM
Low line pressure
|
|
03/11/2021 | ELEC POOL STEEL BOND | Joe Nieves | APPROVED | | 3/9/2021 3:07:24 PM
JS
|
|
03/11/2021 | POOL STEEL | Alejandro Corrales | DISAPPROVED | | 3/9/2021 3:07:45 PM
JS
3/11/2021 1:55:59 PM
1) On page 4 pool wall detail, plan calls for an 8x8 band beam with (3) #3s. Currently the pool only has (1) #3 in the bond beam. Add steel , double check steel against page 4 of plan and reschedule.
|
|
03/16/2021 | MAIN DRAIN | Jeremy Hassenplug | DISAPPROVED | | 3/15/2021 10:09:47 AM
VB
3/16/2021 2:01:51 PM
Low line pressure
|
|
03/16/2021 | POOL STEEL | Alejandro Corrales | APPROVED | | 3/15/2021 10:09:59 AM
VB
|
|
03/18/2021 | MAIN DRAIN | Jan Trana | APPROVED | | 3/17/2021 1:35:25 PM
la
|
|
03/19/2021 | UNDERGROUND | Dean DiBisceglie | APPROVED | | 3/18/2021 3:15:01 PM
JS
|
|
03/19/2021 | ENG ROUGH GRADE | Perry Taborn | APPROVED | | 3/18/2021 3:14:38 PM
JS
3/19/2021 9:36:28 AM
Restore side swales for positive drainage
|
|
03/19/2021 | PERIMETER PIPING | Jan Trana | DISAPPROVED | | 3/18/2021 3:14:50 PM
JS
3/19/2021 1:16:16 PM
Not ready
|
|
05/11/2021 | PERIMETER PIPING | Jeremy Hassenplug | APPROVED | | 5/10/2021 3:47:17 PM
ST
|
|
05/11/2021 | DECK BOND | David Hayes | DISAPPROVED | | 5/10/2021 3:47:43 PM
ST
5/11/2021 4:00:38 PM
1 Please read NEC 680.26 and try again.
2. Please read the installation instructions for the split bolts two conductors max per splice.
|
|
05/18/2021 | DECK BOND | Joe Nieves | DISAPPROVED - FEE | | 5/17/2021 11:25:45 AM
ST
5/18/2021 1:43:47 PM
1) The Equipotential Bond Conductor Must Be Installed 18 To 24 Inches From The Inside Walls Of The Pool.
2) The Bond Conductor Is To (Deep) 4To 6 Inch Maximum From The Underside Of The Deck.
3) The Bond Conductor Must Follow The Contour Of The Pool, And Be Installed In A (Neat And Workmanlike Manner).
4) Add Fill, Raise Conductor, And Straighten Bond Conductor.
NEC 680.26 / 110.12
|
|
05/21/2021 | DECK BOND | Joe Nieves | APPROVED | | 5/20/2021 3:10:24 PM
JS
|
|
07/09/2021 | DECK STEEL/PAVERS | Joseph Robinson | APPROVED | | 7/8/2021 12:25:42 PM
JS
|
|
08/06/2021 | SCREEN BOND | CAP Gov EL | DISAPPROVED | EXISTING #1610-0185 | 8/5/2021 11:03:25 AM
JS
8/6/2021 2:55:25 PM
LOOSE CONNECTIONSNEC 680.26(B)7
|
|
08/12/2021 | FINAL SURVEY | Wyatt T. Haygood | APPROVED | | |
|
09/13/2021 | SCREEN BOND | Joe Nieves | DISAPPROVED | | 9/10/2021 11:23:28 AM
wth
9/13/2021 9:51:52 AM
1) The Bonding Lug @ Screen Must Be Copper, Copper Alloy Or Stainless Steel.
2) The Window Frames Must Be Bonded Into The Equipotential Bond Grid.
NEC 680.7
NEC 680.26 (B) 7
|
|
09/13/2021 | SCREEN ENCLOSURE | Wyatt T. Haygood | APPROVED | EXISTING #1610-0185 | 9/10/2021 11:24:02 AM
wth
|
|
09/13/2021 | SAFETY ACT 515 | Wyatt T. Haygood | APPROVED | | 9/10/2021 11:23:10 AM
wth
|
|
09/21/2021 | ENG MISC | Perry Taborn | APPROVED | | 9/17/2021 2:09:41 PM
JS
|
|
09/21/2021 | SCREEN BOND | Joe Nieves | APPROVED | | 9/17/2021 2:09:25 PM
JS
|
|
10/19/2021 | ELECTRIC FINAL | David Hayes | APPROVED | | 10/18/2021 1:41:52 PM
VB
|
|
10/20/2021 | PLUMBING POOL FINAL | Jeremy Hassenplug | DISAPPROVED | | 10/19/2021 3:22:42 PM
JS
10/20/2021 12:05:22 PM
Piping needs to be labeled
|
|
10/20/2021 | LANDSCAPING | Patti Hoot | APPROVED | | 10/19/2021 3:22:33 PM
JS
10/20/2021 2:38:43 PM
Equipment is screened with podocarpus and roebelenii's installed in rear yard as replacement trees
|
|
10/27/2021 | PLUMBING POOL FINAL | Jeremy Hassenplug | APPROVED | | 10/26/2021 1:16:23 PM
Request For Inspection
City of Parkland Request for Inspection Form
Permit Number 20080266
First Name michelle
Last Name castillo
Company PQS Pool & Patio Renovation
Phone Number 3054690689
Email Address michelle@poolpatioreno.com
Type of Inspection(s) Requested Plumbing Final
Request Date 10/27/2021
Instructions/Example
If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th.
Additional Information
Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to eTRAKiT please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at 954.753.5447.
|
|
10/29/2021 | FINAL** | Alejandro Corrales | DISAPPROVED | | 10/28/2021 1:13:28 PM
MT
10/29/2021 5:31:08 PM
1) Screen enclosure door no longer self-closing and self-latching due to paver elevation outside of screen door. Reset these pavers and reschedule
|
|
11/04/2021 | FINAL** | Alejandro Corrales | APPROVED | | 11/3/2021 1:44:32 PM
MT
|
|