Permit No. POOL2010-0121 Permit Type   POOLS/SPA/REMODEL/WF Site Address   10650 CORAL ST
PARKLAND, FL 33076
Applied   10/09/2020 Applicant  
Approved   12/10/2020 Owner   10650 CORAL STREET LAND TR
Issued   12/15/2020 Contractor   CRAFTMASTER CUSTOM POOLS
Parent Permit No.   Description   POOL/ALARMS/GAS HTR/DECK (EXISTING FENCE #2006-0012)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 01/07/2021NOCDebbie GrosseAPPROVED

 01/13/2021NPDES INITIALPerry TabornAPPROVED1/12/2021 2:19:59 PM JS

 01/15/2021MAIN DRAINJan TranaDISAPPROVED1/14/2021 11:59:09 AM JS 1/15/2021 11:19:27 AM Low line pressure Needs clean fill for perimeter piping.

 01/15/2021ELEC POOL STEEL BONDCarmen Di PaulaAPPROVED1/14/2021 11:58:59 AM JS

 01/15/2021POOL STEELAlejandro CorralesDISAPPROVED1/14/2021 11:59:20 AM JS 1/15/2021 5:23:13 PM Page 1 and 4 of the pool plan calls for "Top 2 feet of pool-spa wall in rear shall be w/ #3@6" ocew". Currently, steel at rear wall is #3 @ 12ocew all the way up.

 01/28/2021MAIN DRAINJan TranaDISAPPROVED1/27/2021 2:14:37 PM JS 1/28/2021 2:35:17 PM Low line pressure

 01/28/2021POOL STEELJoseph RobinsonAPPROVED1/27/2021 2:14:50 PM JS

 02/01/2021MAIN DRAINJeremy HassenplugDISAPPROVED - FEE1/29/2021 9:02:53 AM JS 2/1/2021 12:38:00 PM Low line pressure

 02/02/2021MAIN DRAINJan TranaDISAPPROVED2/1/2021 12:38:17 PM VB 2/2/2021 1:03:28 PM R4501.12.1 Pressure test must be not less than 35 psi

 02/03/2021MAIN DRAINJeremy HassenplugAPPROVED2/2/2021 3:09:05 PM vb

 03/12/2021ENG ROUGH GRADEPerry TabornAPPROVED

 03/12/2021PERIMETER PIPINGJan TranaAPPROVEDNEEDS CLEAN FILL3/12/2021 1:15:13 PM Clean fill for backfill

 03/18/2021DECK BONDDavid HayesAPPROVED3/17/2021 10:55:36 AM ST

 04/02/2021GAS LINE RGH OUT-PLDave Chin-SangAPPROVED

 05/11/2021FENCEWill JorgeAPPROVEDEXISTING #2006-00125/10/2021 10:52:09 AM VB 5/11/2021 2:00:20 PM existing

 05/11/2021ELECTRIC FINALJoe NievesDISAPPROVED - FEE5/10/2021 10:52:47 AM VB 5/11/2021 2:19:36 PM 1) The Connector Fitting Installed @ The Service Panel Will Not Allow The Panel Door To Open As Designed. 2) The Black Used As The Neutral Cannot Be Taped White. 3) Check The Equipment Grounding Conductor Size. NEC 110.3 B NEC 200.4

 05/11/2021FENCE BONDDavid HayesAPPROVEDN/R5/10/2021 10:52:29 AM VB

 05/14/2021ELECTRIC FINALDavid HayesDISAPPROVED5/13/2021 3:42:17 PM JS 5/14/2021 3:27:17 PM Safety Act required prior to final.

 05/14/2021UNDERGROUNDDavid HayesDISAPPROVED5/13/2021 3:42:04 PM JS 5/14/2021 3:27:20 PM Work covered.

 05/18/2021UNDERGROUNDJoe NievesAPPROVED

 05/18/2021ELECTRIC FINALJoe NievesAPPROVED

 05/18/2021DECK STEEL/PAVERSWill JorgeAPPROVED

 05/18/2021SAFETY ACT 515Will JorgeAPPROVED

 06/04/2021FINAL GAS-PLUMBINGJan TranaDISAPPROVED6/3/2021 2:51:02 PM th 6/4/2021 12:42:33 PM 110.9.1 No access

 06/09/2021FINAL GAS-PLUMBINGDave Chin-SangDISAPPROVED - FEE6/4/2021 2:16:57 PM th 6/9/2021 12:16:12 PM Brass vent limiter not allowed on outdoor installation per manufacture installation. Barbecue riser not 12" below grade and needs support. No drop test present wit permit

 06/11/2021FINAL GAS-PLUMBINGJeremy HassenplugAPPROVED6/10/2021 2:31:28 PM th

 07/15/2021ENG MISCPerry TabornAPPROVED7/14/2021 11:15:04 AM JS

 07/28/2021FINAL SURVEYWyatt T. HaygoodAPPROVED

 07/29/2021LANDSCAPINGPatti HootDISAPPROVED7/28/2021 11:38:27 AM th 7/29/2021 10:29:36 AM Equipment needs to be screened front and back and still needs either one tree or one more triple palm in rear yard as replacement for trees removed

 08/10/2021LANDSCAPINGPatti HootAPPROVED8/9/2021 3:59:57 PM JS 8/10/2021 11:42:29 AM Screened with podocarpus

 08/18/2021PLUMBING POOL FINALJeremy HassenplugDISAPPROVED8/17/2021 4:11:56 PM ST 8/18/2021 2:17:26 PM Pump doesn't match plans

 09/03/2021PLUMBING POOL FINALJeremy HassenplugAPPROVED

 09/07/2021FINAL**Tony WillsonAPPROVED