  Date of Inspection Inspection Type Inspector Result Remarks Notes

 04/19/2021NOCDebbie GrosseAPPROVED

 05/11/2021NPDES INITIALPerry TabornAPPROVED

 05/12/2021ELEC POOL STEEL BONDDean DiBisceglieAPPROVED

 05/13/2021POOL STEELJoseph RobinsonAPPROVED

 05/13/2021MAIN DRAINJeremy HassenplugDISAPPROVED5/13/2021 2:36:29 PM Low line pressure

 05/18/2021MAIN DRAINJeremy HassenplugAPPROVED

 06/11/2021UNDERGROUNDCAP Gov ELAPPROVED

 06/11/2021PERIMETER PIPINGJeremy HassenplugAPPROVED

 06/22/2021DECK BONDJoe NievesAPPROVED

 08/19/2021DECK STEEL/PAVERSJoseph RobinsonAPPROVED

 08/19/2021ENG ROUGH GRADEPerry TabornAPPROVED8/19/2021 11:55:16 AM Restore disturbed areas in rear and side swales

 08/25/2021SAFETY ACT 515Joseph RobinsonDISAPPROVED8/24/2021 10:41:07 AM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21020181 First Name Joel Last Name Ferrer Company VALERO POOLS INC Phone Number 9542921218 Email Address Valeropools@gmail.com Type of Inspection(s) Requested SAFETY ACT 515 FENCE BOND FENCE Request Date 8/25/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to Etrakit please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at (954) 753-5447. 8/25/2021 12:49:59 PM Not ready. UL2017 approved window alarms not installed. If an in pool alarm will be used, submit a COP.

 08/25/2021FENCEJoseph RobinsonAPPROVED8/24/2021 10:41:21 AM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21020181 First Name Joel Last Name Ferrer Company VALERO POOLS INC Phone Number 9542921218 Email Address Valeropools@gmail.com Type of Inspection(s) Requested SAFETY ACT 515 FENCE BOND FENCE Request Date 8/25/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to Etrakit please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at (954) 753-5447.

 08/25/2021FENCE BONDJoe NievesAPPROVED8/24/2021 10:42:31 AM Request For Inspection City of Parkland Request for Inspection Form Permit Number 21020181 First Name Joel Last Name Ferrer Company VALERO POOLS INC Phone Number 9542921218 Email Address Valeropools@gmail.com Type of Inspection(s) Requested SAFETY ACT 515 FENCE BOND FENCE Request Date 8/25/2021 Instructions/Example If you desire an inspection on the 28th, your request must be submitted by 4:00PM on the 27th. Additional Information Contractors can schedule inspections online by going to https://www.cityofparkland.org/epermit. If you are a contractor and do not have access to Etrakit please contact the Building Department to get directions for scheduling inspections online. Contractors can cancel inspections online up to 6:00am via the online portal. Same day inspection cancellations you must contact the Building Department via telephone between 7:30 and 8:00 AM at (954) 753-5447. 8/25/2021 1:38:02 PM Fence Bond Not Required. 8/25/2021 2:13:40 PM Fence Bond Not Required.

 08/27/2021SAFETY ACT 515Alejandro CorralesAPPROVED

 09/02/2021ELECTRIC FINALJoe NievesDISAPPROVED - FEE9/2/2021 9:39:25 AM 1) The Number 8 AWG Wire Taped White Is A Violation. NEC 200.6 2) The Number 8 AWG Wire Taped Green Is A Violation. NEC 250.119 3) The Gas Water Heater For The Pool Must Be Protected With A GFCI Type Circuit Breaker. NEC 680.28 4) The Schedule 40 PVC Installed Is Subject To Physical Damage. NEC 352.12 5) The Circuit Breaker Feeding The Pool Panel Has Not Been Installed. FBC 110.9.1 9/2/2021 9:54:03 AM 1) The Number 8 AWG Wire Taped White Is A Violation. NEC 200.6 2) The Number 8 AWG Wire Taped Green Is A Violation. NEC 250.119 3) The Gas Water Heater For The Pool Must Be Protected With A GFCI Type Circuit Breaker. NEC 680.28 4) The Schedule 40 PVC Installed Is Subject To Physical Damage. NEC 352.12 5) The Circuit Breaker Feeding The Pool Panel Has Not Been Installed. FBC 110.9.1

 09/07/2021ELECTRIC FINALJoe NievesDISAPPROVED9/7/2021 11:40:22 AM No Access Into Pool Panel, Panel Cover Screws Are Impacted In Place. No Access / FBC 110.9.1

 09/24/2021FINAL GAS-PLUMBINGJan TranaDISAPPROVED9/23/2021 3:00:51 PM MT 9/24/2021 11:52:30 AM Not ready

 09/27/2021GAS LINE RGH OUT-PLJeremy HassenplugDISAPPROVED9/24/2021 4:42:57 PM JS 9/27/2021 12:40:06 PM Work not to plan and permit card not on site

 09/30/2021GAS LINE RGH OUT-PLJan TranaAPPROVED9/29/2021 2:06:33 PM vb 9/30/2021 1:05:54 PM Need COP by final BBQ needs to be deleted

 10/15/2021FINAL GAS-PLUMBINGJan TranaAPPROVED10/14/2021 11:54:06 AM st

 11/19/2021ENG MISCPerry TabornAPPROVED

 04/21/2022ELECTRIC FINALDean DiBisceglieAPPROVEDno permit to sign4/20/2022 8:47:21 AM MT

 04/21/2022PLUMBING POOL FINALJeremy HassenplugAPPROVED4/20/2022 8:47:41 AM MT

 04/26/2022FINAL SURVEYBill TracyAPPROVED

 04/28/2022LANDSCAPINGPatti HootAPPROVED4/27/2022 3:51:32 PM VB

 05/03/2022FINAL**Wyatt T. HaygoodAPPROVED