05/05/2024
4:09 PM
 
Permit No. POOL2105-0332 Permit Type   POOLS/SPA/REMODEL/WF Site Address   8850 EDGEWATER PL
PARKLAND, FL 33076
Applied   05/27/2021 Applicant  
Approved   08/02/2021 Owner   VAYNMAN, ARTHUR H/E
Issued   08/06/2021 Contractor   POOL BUILDERS INC
Parent Permit No.   Description   POOL/ALARMS/NG HTR/DECK (EXISTING FENCE #2101-0158)
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 09/01/2021NPDES INITIALPerry TabornAPPROVEDeTRAKiT Inspection Request8/31/2021 2:18:44 PM 8/31/2021 2:18 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 09/02/2021NOCDebbie GrosseAPPROVED

 09/16/2021MAIN DRAINJan TranaAPPROVEDeTRAKiT Inspection Request9/15/2021 9:01:06 AM 9/15/2021 9:01 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 09/16/2021ELEC POOL STEEL BONDJoe NievesAPPROVEDeTRAKiT Inspection Request9/15/2021 9:01:13 AM 9/15/2021 9:01 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 09/16/2021POOL STEELAlejandro CorralesDISAPPROVEDeTRAKiT Inspection Request9/15/2021 9:00:59 AM 9/15/2021 9:00 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM 9/16/2021 3:29:32 PM 1) Bond beam on both sides of sun shelf is incomplete. One side just missing a corner bar with minimum 12" lap and the other side is incomplete. Double bond beam is not continuous. 2) plan calls for pool wall between pool and catch basin to be #3 @ 6" on center each way. Currently, this wall is at 12" ocew.

 09/22/2021POOL STEELWill JorgeAPPROVEDeTRAKiT Inspection Request9/21/2021 4:11:49 PM 9/21/2021 4:11 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 12/09/2021UNDERGROUNDDean DiBisceglieAPPROVEDeTRAKiT Inspection Request12/8/2021 6:52:41 AM 12/8/2021 6:52 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 12/09/2021PERIMETER PIPINGJan TranaAPPROVEDeTRAKiT Inspection Request12/8/2021 6:52:48 AM 12/8/2021 6:52 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 12/22/2021DECK BONDCAP Gov ELAPPROVEDeTRAKiT Inspection Request12/21/2021 1:42:01 PM 12/21/2021 1:42 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 03/04/2022ENG ROUGH GRADEPerry TabornAPPROVEDeTRAKiT Inspection Request3/3/2022 8:52:31 AM 3/3/2022 8:52 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 03/04/2022DECK STEEL/PAVERSWyatt T. HaygoodAPPROVEDeTRAKiT Inspection Request3/3/2022 8:52:43 AM 3/3/2022 8:52 AM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 03/17/2022GAS LINE RGH OUT-PLJeremy HassenplugAPPROVED3/16/2022 10:00:50 AM MT

 03/17/2022SAFETY ACT 515Joseph RobinsonDISAPPROVEDeTRAKiT Inspection Request3/16/2022 1:07:47 PM 3/16/2022 1:07 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM 3/17/2022 3:54:37 PM All gates must be self closing self latching. Work incomplete.

 03/17/2022FENCEJoseph RobinsonDISAPPROVEDeTRAKiT Inspection Request3/16/2022 1:07:55 PM 3/16/2022 1:07 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM 3/17/2022 3:54:38 PM All gates must be self closing self latching. Work incomplete.

 03/22/2022SAFETY ACT 515Joseph RobinsonAPPROVEDeTRAKiT Inspection Request3/21/2022 3:03:21 PM 3/21/2022 3:03 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 03/22/2022FENCEJoseph RobinsonAPPROVEDeTRAKiT Inspection Request3/21/2022 3:05:36 PM 3/21/2022 3:05 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM

 03/24/2022ELECTRIC FINALCAP Gov ELDISAPPROVEDeTRAKiT Inspection Request3/23/2022 2:56:10 PM 3/23/2022 2:56 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM 3/25/2022 8:43:02 AM 1- Breakers for pool gas water heater, pool lights, speck PUMP shall be GFCI PROTECTED NEC 110.3 2- no GFCI OUTLET 6 ft away from the pool and closer than 20 ft. NEC 680 3- Badu controller cables shall be installed in neat and workman like manner 4- change of plan req. to the latest version dated 1-12-22 feeder still shows 80amp, 60 amp should be installed

 05/04/2022ELECTRIC FINALDean DiBisceglieAPPROVED5/3/2022 10:36:52 AM ST

 05/06/2022ENG MISCPerry TabornAPPROVED5/5/2022 9:16:02 AM vb

 05/06/2022FINAL GAS-PLUMBINGJan TranaDISAPPROVED5/5/2022 9:16:28 AM vb 5/6/2022 12:34:25 PM Not ready

 05/06/2022PLUMBING POOL FINALJan TranaAPPROVED5/5/2022 9:16:43 AM vb

 05/24/2022FINAL GAS-PLUMBINGJan TranaAPPROVED5/23/2022 2:56:17 PM VB

 06/24/2022LANDSCAPINGPatti HootDISAPPROVED5/5/2022 9:17:03 AM vb 6/24/2022 1:48:20 PM Equipment needs to be screened

 07/18/2022FINAL SURVEYGayle EasterlingDISAPPROVED7/19/2022 9:17:58 AM Provide South Side Rear Setback to Edge of Water. Minimum 10 Ft. required

 08/04/2022LANDSCAPINGPatti HootAPPROVED8/4/2022 8:49:20 AM vb 8/4/2022 11:39:16 AM Rear yard is landscaped and equipment is screened

 08/10/2022FINAL SURVEYWyatt T. HaygoodAPPROVED

 08/18/2022FINAL**Joseph RobinsonAPPROVEDeTRAKiT Inspection Request8/17/2022 3:27:50 PM 8/17/2022 3:27 PM POOL BUILDERS INC Contact Name: POOL BUILDERS INC Site Address: 8850 EDGEWATER PL Phone: 9547977700 e-Mail: SWIMATPBI@AOL.COM