06/02/2022 | NOC | Marcia Turner | APPROVED | | |
|
06/29/2022 | NPDES INITIAL | Perry Taborn | APPROVED | eTRAKiT Inspection Request | 6/28/2022 5:03:21 PM
6/28/2022 5:03 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
|
|
07/29/2022 | MAIN DRAIN | Jan Trana | APPROVED | eTRAKiT Inspection Request | 7/28/2022 10:27:12 PM
7/28/2022 10:27 PM STREAMLINE POOLS AND SPAS INC
Please come after 12pm
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
|
|
07/29/2022 | ELEC POOL STEEL BOND | Pedro Vieira | APPROVED | eTRAKiT Inspection Request | 7/28/2022 10:26:45 PM
7/28/2022 10:26 PM STREAMLINE POOLS AND SPAS INC
Please come after 12pm
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
|
|
07/29/2022 | POOL STEEL | Wyatt T. Haygood | APPROVED | eTRAKiT Inspection Request | 7/28/2022 10:27:36 PM
7/28/2022 10:27 PM STREAMLINE POOLS AND SPAS INC
Please come after 12pm
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
|
|
09/13/2022 | PERIMETER PIPING | Jeremy Hassenplug | APPROVED | | 9/12/2022 4:29:16 PM
VB
|
|
09/13/2022 | UNDERGROUND | David Hayes | APPROVED | | 9/12/2022 4:29:25 PM
VB
|
|
09/13/2022 | DECK BOND | David Hayes | DISAPPROVED | SEE NOTES | 9/12/2022 4:29:35 PM
VB
9/13/2022 2:16:17 PM
A #8 cu conductor shall be attached to the pool reinforcing steel or copper conductor grid at a minimum of four (4) points that are visible for inspection, uniformly spaced around the perimeter of the pool and then follow the points below:
(1) At least one minimum 8 AWG bare solid copper conductor shall be provided.
(2) The conductors shall follow the contour of the perimeter surface.
(3) Only listed splices shall be permitted.
(4) The required conductor shall be 450 mm to 600 mm (18 in. to 24 in.) from the inside walls of the pool.
(5) The required conductor shall be secured within or under the perimeter surface 100 mm to 150 mm (4 in. to 6 in.) below the subgrade.
Provide a secure safety barrier 360b0 around the perimeter of the pool in compliance with the pool safety act. FBC
|
|
10/14/2022 | DECK BOND | Joe Nieves | DISAPPROVED | eTRAKiT Inspection Request | 10/13/2022 8:24:47 PM
10/13/2022 8:24 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: dmartins@smartypools.com
10/14/2022 1:38:43 PM
Work Not Complete/FBC 110.9.1
|
|
10/17/2022 | DECK BOND | David Hayes | DISAPPROVED - FEE | eTRAKiT Inspection Request | 10/16/2022 11:20:27 PM
10/16/2022 11:20 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9545410595
e-Mail: dmartins@smartypools.com
10/17/2022 2:52:36 PM
Still many errors read the back of thr previous tag
|
|
10/19/2022 | DECK BOND | David Hayes | APPROVED | | |
|
11/09/2022 | GAS LINE RGH OUT-PL | Jan Trana | APPROVED | | |
|
01/12/2023 | ENG ROUGH GRADE | Perry Taborn | APPROVED | | 1/11/2023 2:52:05 PM
MT
|
|
01/12/2023 | FENCE BOND | Joe Nieves | APPROVED | | 1/11/2023 2:52:34 PM
MT
1/12/2023 1:21:19 PM
Fence Bond Not Required.
|
|
01/12/2023 | FENCE | Alejandro Corrales | DISAPPROVED | | 1/11/2023 2:52:49 PM
MT
1/12/2023 3:44:33 PM
Posts next to left fence gate are loose and lift out of the ground. Dig out these post footers and add more concrete.
|
|
01/17/2023 | FENCE | Wyatt T. Haygood | DISAPPROVED | eTRAKiT Inspection Request | 1/16/2023 10:23:51 AM
1/16/2023 10:23 AM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9545410595
e-Mail: support@smartypools.com
1/17/2023 3:22:18 PM
Gate latch at left side of home required to be minimum 54 inch above bottom of gate to latch.
Gate at rear of property not self closing and latching.
|
|
01/26/2023 | FENCE | Joseph Robinson | APPROVED | eTRAKiT Inspection Request | 1/25/2023 9:46:51 PM
1/25/2023 9:46 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
|
|
01/17/2023 | DECK STEEL/PAVERS | Wyatt T. Haygood | DISAPPROVED | eTRAKiT Inspection Request | 1/16/2023 10:25:38 AM
1/16/2023 10:25 AM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9545410595
e-Mail: support@smartypools.com
1/17/2023 3:22:19 PM
Deck not same shape as per plan.
Additional walkway and front entry paver extension not shown on plans.
Toe kick mortar incomplete at misc. areas for pavers.
Mortar required around entire paver perimeter.
|
|
01/12/2023 | DECK STEEL/PAVERS | Alejandro Corrales | DISAPPROVED | | 1/11/2023 2:52:16 PM
MT
1/12/2023 3:44:34 PM
Pavers loose at rear right portion of deck near steps. Check all other paver edges for adhesion and reschedule
|
|
01/26/2023 | DECK STEEL/PAVERS | Joseph Robinson | DISAPPROVED | eTRAKiT Inspection Request | 1/25/2023 9:47:04 PM
1/25/2023 9:47 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
1/26/2023 3:39:57 PM
Same as previous disapproval.
|
|
02/08/2023 | SAFETY ACT 515 | Wyatt T. Haygood | CANCELLED BY PERMITE | | |
|
02/08/2023 | ELECTRIC FINAL | Pedro Vieira | DISAPPROVED | | 2/8/2023 1:51:08 PM
Work not complete
|
|
02/09/2023 | SAFETY ACT 515 | Joseph Robinson | DISAPPROVED | | 2/8/2023 7:59:45 AM
wth
2/9/2023 11:59:53 AM
No answer at door.
|
|
02/09/2023 | ELECTRIC FINAL | Joe Nieves | DISAPPROVED | eTRAKiT Inspection Request | 2/8/2023 3:40:32 PM
2/8/2023 3:40 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
2/9/2023 1:29:41 PM
1) Circuit Identification @ Pool Panel (Must) Be Labels Suitable For The Environment/NEC 110.22
2) The Circuit Breaker Used For The Blower, Is Not Listed For Use In The Panel/NEC 110.3 (B)
3) Unused Opening @ Bottom Of Pool Panel Must Be Closed/NEC 110.12
|
|
02/10/2023 | SAFETY ACT 515 | Will Jorge | APPROVED | | |
|
02/10/2023 | ELECTRIC FINAL | Pedro Vieira | DISAPPROVED - FEE | eTRAKiT Inspection Request | 2/10/2023 4:07:53 AM
2/10/2023 4:07 AM STREAMLINE POOLS AND SPAS INC
please come in the afternoon
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: STREAMLINEPOOLS@YAHOO.COM
2/10/2023 3:02:33 PM
Nec 356.42 - liquidtight flex shall be terminated on listed fittings
Nec 110.22 - main breaker shall be labeled and identified for the purpose
|
|
02/14/2023 | ELECTRIC FINAL | Pedro Vieira | APPROVED | CHECK PAYMENTS HAVE BEEN MADE.TTL $189 | 2/13/2023 1:58:10 PM
CHECK LATE PAYMENTS HAVE BEEN MADE.TTL $189
|
|
06/09/2023 | PLUMBING POOL FINAL | Jeremy Hassenplug | DISAPPROVED | | 6/8/2023 8:57:47 AM
vb
6/9/2023 10:49:39 AM
Back flow not installed
6/9/2023 10:54:01 AM
Backflow not installed
|
|
07/12/2023 | FINAL GAS-PLUMBING | Dave Chin-Sang | APPROVED | | |
|
08/17/2023 | BACKFLOW FINAL | Jeremy Hassenplug | DISAPPROVED | | 8/16/2023 1:03:53 PM
MT
8/17/2023 11:04:22 AM
Check valve installed is not sufficient a duel check or better is required
|
|
08/17/2023 | LANDSCAPING | Patti Hoot | APPROVED | LAND2306-0228 TURF | 8/16/2023 1:04:12 PM
MT
8/17/2023 2:34:48 PM
See landscape photos with turf permit
|
|
08/17/2023 | ENG MISC | Jamiko Sands | APPROVED | | 8/16/2023 1:03:35 PM
MT
|
|
09/01/2023 | BACKFLOW FINAL | Jan Trana | APPROVED | eTRAKiT Inspection Request | 8/31/2023 8:42:07 PM
8/31/2023 8:42 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9544794462
e-Mail: dmartins@smartypools.com
|
|
09/01/2023 | PLUMBING POOL FINAL | Jan Trana | APPROVED | eTRAKiT Inspection Request | 8/31/2023 8:39:53 PM
8/31/2023 8:39 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9545410595
e-Mail: dmartins@smartypools.com
|
|
09/01/2023 | DECK STEEL/PAVERS | Anthony Crisanti | APPROVED | eTRAKiT Inspection Request | 2/7/2023 4:09:16 PM
COP BROUGHT IN, CHANGING LAYOUT OF DECK AS REQUESTED BY PROPERTY OWNER
8/31/2023 8:38:57 PM
8/31/2023 8:38 PM STREAMLINE POOLS AND SPAS INC
Contact Name: STREAMLINE POOLS AND SPAS INC
Site Address: 8681 LAKESIDE BND
Phone: 9545410595
e-Mail: dmartins@smartypools.com
|
|
10/04/2023 | FINAL SURVEY | Jean Panebianco | DISAPPROVED | | 10/4/2023 8:05:30 AM
Fence appears to be installed outside of property line. Survey submitted shows 2.1 rear setback for pavers. Plans approved are for a 5' rear setback for pavers.
|
|
02/06/2024 | FINAL SURVEY | Bill Tracy | APPROVED | | |
|
02/07/2024 | FINAL** | Anthony Crisanti | APPROVED | CHECK PAYMENTS HAVE BEEN MADE.TTL $ | 2/13/2023 2:01:28 PM
CHECK LATE PAYMENTS HAVE BEEN MADE.TTLCHECK LATE PAYMENTS HAVE BEEN MADE.TTL $189
2/6/2024 4:10:44 PM
JS
|
|