05/18/2023 | NOC | Stephanie Taylor | APPROVED | | |
|
05/30/2023 | NPDES INITIAL | Perry Taborn | APPROVED | | 5/25/2023 9:24:41 AM
ST
5/30/2023 8:52:57 AM
Maintain silt fence, needs to be entrenched
|
|
05/31/2023 | ELEC POOL STEEL BOND | Rinor Krasniqi | APPROVED | | 5/30/2023 2:29:33 PM
JS
|
|
05/31/2023 | MAIN DRAIN | Jeremy Hassenplug | APPROVED | | 5/30/2023 2:29:40 PM
JS
|
|
05/31/2023 | POOL STEEL | Alejandro Corrales | DISAPPROVED | | 5/30/2023 2:29:48 PM
JS
5/31/2023 3:24:38 PM
1) Excavations within 5 feet of existing foundations and footers must be protected with shoring.
2) Floor steel must be raised up a minimum of 3 inches above the ground.
3) Plan calls for steel around the skimmer to be #4 steel.
|
|
05/31/2023 | POOL STEEL | Alejandro Corrales | APPROVED | | |
|
06/09/2023 | UNDERGROUND | Joe Nieves | APPROVED | REQUESTING EARLY AM | 6/9/2023 12:00:32 PM
JS
6/9/2023 12:15:55 PM
OK TO SCHEDULE SAME DAY PER JOE N
|
|
06/12/2023 | PERIMETER PIPING | Jeremy Hassenplug | APPROVED | REQUESTING EARLY AM | 6/9/2023 12:00:14 PM
JS
|
|
06/15/2023 | ENG ROUGH GRADE | Perry Taborn | APPROVED | | 6/14/2023 2:19:56 PM
ST
|
|
06/21/2023 | DECK BOND | Rinor Krasniqi | DISAPPROVED | | 6/20/2023 11:20:15 AM
ST
6/21/2023 12:01:44 PM
No visible conductor buried
|
|
06/22/2023 | DECK BOND | Rinor Krasniqi | APPROVED | | 6/21/2023 4:13:44 PM
MT
|
|
06/27/2023 | DECK STEEL/PAVERS | Alejandro Corrales | APPROVED | | 6/26/2023 9:47:13 AM
VB
|
|
06/28/2023 | FENCE BOND | Rinor Krasniqi | APPROVED | | 6/27/2023 11:11:12 AM
FM
6/28/2023 12:02:29 PM
NOT APPLICABLE / REQUIRED
|
|
06/28/2023 | FENCE | Alejandro Corrales | APPROVED | EXISTING #2203-0023 | 6/27/2023 11:10:52 AM
FM
|
|
07/03/2023 | SAFETY ACT 515 | Joseph Robinson | APPROVED | | 6/30/2023 10:41:26 AM
FM
|
|
07/11/2023 | FINAL SURVEY | Wyatt T. Haygood | APPROVED | | |
|
07/12/2023 | ENG MISC | Perry Taborn | APPROVED | | 7/11/2023 1:28:26 PM
an
|
|
07/12/2023 | ELECTRIC FINAL | Rinor Krasniqi | DISAPPROVED | | 7/11/2023 1:22:55 PM
an
7/12/2023 10:31:38 AM
408.4 labeling she'll be done so to withstand the environment
110.14 make sure all terminations are proper, no insulation and termination, and no wire strands sticking out of termination
110.9.1 Work is not to plan, plan asks for 80 amp breaker for the pool panel
HOMEOWNER NOTIFIED OF SINGLE SWITCH FOR LED CONTROL. HOMEOWNER WAS OK WITH IT.
|
|
07/13/2023 | ELECTRIC FINAL | Joe Nieves | APPROVED | | 7/12/2023 2:01:57 PM
mt
|
|
07/13/2023 | LANDSCAPING | Patti Hoot | APPROVED | | 7/11/2023 1:23:42 PM
an
7/13/2023 1:14:30 PM
Check for Rearvyard shade trees from BC PA
|
|
07/14/2023 | PLUMBING POOL FINAL | Jeremy Hassenplug | APPROVED | | 7/13/2023 1:56:35 PM
ST
|
|
07/17/2023 | FINAL** | Joseph Robinson | APPROVED | | 7/14/2023 2:27:41 PM
MT
|
|